Abbonarsi

A novel device for improving visualization in an inadequately prepared colon - 21/02/18

Doi : 10.1016/j.gie.2017.10.028 
Seth A. Gross, MD 1, ⁎, Lauren B. Gerson, MD 2 : deceased, Blair S. Lewis, MD 3, Robert A. Ganz, MD 4
1 Tisch Hospital, NYU Langone Medical Center, New York, New York, USA 
2 California Pacific Medical Center, San Francisco, California, USA 
3 Carnegie Hill Endoscopy, New York, New York, USA 
4 Minnesota Gastroenterology P.A., Minnesota, USA 

∗Reprint requests: Seth A. Gross, MD, FASGE, Chief of Gastroenterology, Tisch Hospital, Associate Professor of Medicine, NYU Langone Medical Center, New York, NY 10016.Chief of GastroenterologyTisch HospitalAssociate Professor of MedicineNYU Langone Medical CenterNew YorkNY10016

Abstract

Background and Aims

Adequate bowel preparation is crucial for a quality colonoscopy. Poor bowel preparation can result in longer procedural times, missed adenomas, earlier repeat procedures, increase costs, and decreased patient satisfaction. Pure-Vu (MOTUS GI, Tirat Carmel, Israel) is a system that facilitates intraprocedural cleaning of a poorly prepared colon during a colonoscopy by irrigating the colon and evacuating the fluid and feces. The study aims were to evaluate Pure-Vu’s cleansing capabilities and its usability and safety in a live animal colon.

Methods

The Pure-Vu system was used by 4 experienced gastroenterologists in 35 Yorkshire cross swine (66% female) that received a reduced bowel preparation to ensure an inadequate bowel preparation at baseline. Before colonoscopy the Pure-Vu was attached to the colonoscope, and the baseline prep was assessed during insertion. The Pure-Vu system was then used to cleanse the colon and the prep then assessed after Pure-Vu use.

Results

No adverse effects and no failed or prematurely terminated cases were noted. Fourteen percent of the swine colons were adequately prepped at baseline (median Boston Bowel Preparation Scale [BBPS] score = 0 [25th percentile = 0; 75th percentile = 1; interquartile range = 1]) and improved to 100% after use of Pure-Vu (Wilcoxon signed rank test P < .001) (median BBPS score = 3 [25th percentile = 3; 75th percentile = 3; interquartile range = 0]). The physicians found Pure-Vu easy and intuitive to operate.

Conclusions

The Pure-Vu system effectively cleaned inadequately prepped swine colons and proved to be easy to use. The Pure-Vu device, applied in clinical practice, may result in improved overall prep quality and a reduction in repeat examinations because of inadequately prepped colons.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : BBPS, IQR


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Gross at [email protected].


© 2018  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 87 - N° 3

P. 883-888 - marzo 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Rectal EMR for enteric ganglia: Is deeper better?
  • Christine Yu, Satish S.C. Rao
| Articolo seguente Articolo seguente
  • A novel method to prevent catheter dysfunction during spray cryotherapy
  • Kavel Visrodia, Liam Zakko, Theresa Nolte, Kenneth K. Wang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.