Abbonarsi

Corticocancellous bone graft vs cancellous bone graft for the management of unstable scaphoid nonunion - 23/02/18

Doi : 10.1016/j.otsr.2017.11.011 
J.K. Kim a, , J.O. Yoon a, H. Baek b
a Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea 
b Department of Orthopedic Surgery, Ewha Womans Universtiy Mokdong Hospital, Seoul, South Korea 

Corresponding author. Department of Orthopedic Surgery Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic road 43-gil, Songpa-gu, Seoul 05505, South Korea.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

This study was undertaken to determine whether corticocancellous bone grafting and cancellous bone grafting differ in terms of bone union rate, restoration of scaphoid anatomy, and wrist function when unstable scaphoid nonunions are concomitantly treated by screw fixation.

Materials and methods

This is retrospective cohort study. In Group A (17 patients), unstable scaphoid nonunion was treated with corticocancellous graft harvested from the iliac crest and headless compression screw using volar approach. In Group B (18 patients), unstable scaphoid nonunion was treated with cancellous graft harvested from the distal radius or iliac crest and headless compression screw using volar approach Mean time to union was measured using CT image. Scaphoid deformity was also measured using lateral intrascaphoid angle and height to length ratio using CT images. Wrist functional status was assessed by measuring grip strength, wrist range of motion, and DASH score at 1 year postoperatively.

Results

Mean time to union was significantly greater in Group A (15 weeks vs. 11 weeks). No significant intergroup difference was observed for lateral intrascaphoid angle and height to length ratio after treatment of scaphoid nonunion. No significant intergroup difference was observed for grip strength, wrist range of motion, or DASH scores at 1 year postoperatively.

Conclusions

Cancellous bone grafting was found to lead to earlier bone union than corticocancellous bone grafting and to similar restorations of scaphoid deformity and wrist function when scaphoid nonunion was treated by headless compression screw fixation and bone grafting.

Level of evidence

Prognostic, III.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Unstable scaphoid nonunion, Cancellous bone graft, Corticocancellous bone graft


Mappa


© 2017  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 1

P. 115-120 - febbraio 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Scaphoid screw fixation perpendicular to the fracture plane: Comparing volar and dorsal approaches
  • P.W.L. ten Berg, J.G.G. Dobbe, M.E. Brinkhorst, G. Meermans, S.D. Strackee, F. Verstreken, G.J. Streekstra
| Articolo seguente Articolo seguente
  • Results and complications of superficialis-to-profundus tendon transfer in brain-damaged patients, a series of 26 patients
  • E. Peraut, L. Taïeb, C. Jourdan, F. Coroian, I. Laffont, M. Chammas, B. Coulet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.