Abbonarsi

Measurement variability of liver metastases from neuroendocrine tumors on different magnetic resonance imaging sequences - 28/02/18

Doi : 10.1016/j.diii.2017.12.009 
T. Lestra a, , L. Kanagaratnam b, S. Mulé a, A. Janvier a, H. Brixi c, G. Cadiot c, A. Dohan d, C. Hoeffel a, e
a Department of radiology, Reims university hospital, 51092 Reims, France 
b Department of research and innovation, Reims university hospital, 51100 Reims, France 
c Department of gasto-enterology, Reims university hospital, 51100 Reims, France 
d Department of radiology A, Hopital Cochin, and University Paris 5-Descartes, 75014 Paris, France 
e Reims university hospital, CRESTIC, Champagne-Ardenne university, 51867 Reims, France 

Corresponding author. Department of radiology, CHU de Reims, hôpital Maison-Blanche, 45, rue Cognacq-Jay, 51092 Reims cedex, France.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To assess dimension measurement variability of liver metastases from neuroendocrine tumors (LMNET) on different magnetic resonance imaging (MRI) sequences.

Material and methods

In this institutional review board-approved retrospective study from January 2011 to December 2012, all liver MRI examinations performed at our department in patients with at least one measurable LMNET according to response evaluation criteria in solid tumors (RECIST1.1) were included. Up to two lesions were selected on T2-weighted MR images. Three reviewers independently measured long axes of 135 hepatic metastases in 30 patients (16 men, 14 women, mean age 61±11.4 (SD) years; range 28–78 years), during two separate reading sessions, on T2-weighted, diffusion-weighted MRI (DWI) (b; 50, 400, 800 s/mm2) and arterial, portal and late phases after intravenous administration of a gadolinium chelate. Intraclass-correlation coefficients and Bland–Altman plots were used to assess intra-and interobserver variability.

Results

Intra- and interobserver agreements ranged between 0.87–0.98, and 0.88–0.97, respectively. Intersequence agreements ranged between 0.92 [95%CI: 0.82–0.98] and 0.98 [95%CI: 0.93–0.99]. 95% limits of agreement for measurements were −10.2%,+8.9% for DWI (b=50s/mm2) versus −21.9%,+24.2% and −15.8,+17.2% for arterial and portal phases, respectively.

Conclusion

An increase<9% in measurement and a decrease of −10% on DWI should not be considered as true changes, with 95% confidence, versus 24% and −22% on arterial and 17%, −16% on portal phases, respectively. DWI might thus be the most reliable MR sequence for monitoring size variations of LMNETs.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Liver metastasis, Neuroendocrine tumors (NET), Magnetic resonance imaging (MRI), Response evaluation criteria in solid tumors (RECIST), Interobserver variability


Mappa


© 2017  Editions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 2

P. 73-81 - Febbraio 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Correlation of quantitative MR imaging findings with symptoms in patients with incidentally detected inflammatory sinonasal disease
  • O. Kilickesmez, O. Onerci Celebi, M. Yalcinkaya, A.R. Gokduman, Y. Karagoz, O. Yigit
| Articolo seguente Articolo seguente
  • Volumetric measurement of hepatic tumors: Accuracy of manual contouring using CT with volumetric pathology as the reference method
  • L.F. Pupulim, M. Ronot, V. Paradis, S. Chemouny, V. Vilgrain

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.