Abbonarsi

Heart automaticity in mice lacking L-type Cav1.3 and T-type Cav3.1 Ca2+ channels: Insights into the cardiac pacemaker mechanism - 26/03/18

Doi : 10.1016/j.acvdsp.2018.02.136 
M. Baudot 1, , P. Mesirca 1, A.G. Torrente 1, I. Bidaud 1, L. Fossier 1, L. Talssi 1, H.S. Shin 2, J. Striessnig 3, J. Nargeot 1, S. Barrère-Lemaire 1, M. Mangoni 1
1 Institut de génomique fonctionnelle, CNRS-Inserm, université de Montpellier, Montpellier, France 
2 Korea institute of science and technology, Seoul, South Korea 
3 Institute of Pharmacy, Innsbruck, Austria 

Corresponding author.

Riassunto

Introduction

Sino-atrial node (SAN) pacemaker activity is generated by ion channels of the plasma membrane, such as hyperpolarization-activated “funny” f-(HCN), Ca2+ channels and ryanodine receptor (RyR) – dependent Ca2+ release from the sarcoplasmic reticulum (SR). It is currently disputed whether Ca2+ release from RyRs could sustain viable pacemaker activity provided preserved SR Ca2+ content. While working myocytes express L-type Cav1.2 channels to maintain SR Ca2+ content, SAN cells express also L-type Cav1.3 and T-type Cav3.1 channels to generate pacemaking.

Objectives

We used mutant mice carrying concomitant ablation of Cav1.3 and Cav3.1 (Cav1.3−/−/Cav3.1−/−) to study the importance of these channels in automaticity. We also investigated the role of f-HCN channels and RyR-dependent Ca2+ release in residual pacemaker activity of mutant mice.

Methods

We employed in vivo telemetric recordings of heart rate (HR) in Cav1.3−/−, Cav3.1−/− and Cav1.3−/−/Cav3.1−/− mice. We studied the consequences of pharmacologic inhibition of f-HCN and TTX-sensitive Na+ channels in mutant mice using Langendorff perfused hearts or optical mapping (OM) of the pacemaker impulse in intact SAN preparations (SANs).

Results

Cav ablation reduced HR in mice: Cav3.1−/− (−7.6%, n=11), Cav1.3−/− (−24.4%, n=8), Cav1.3−/−/Cav3.1−/− (−35%, n=11). In OM experiments on SANs, concomitant inhibition of f-HCN and Nav1.1 channels slowed pacemaking in wild-type (−48%, n=7) and Cav3.1−/− (−37%, n=7), while arresting automaticity in 4/6 of Cav1.3−/−, 3/6 of Cav1.3−/−/Cav3.1−/−. When present, residual pacemaking was reduced by 82%. Similar results were obtained using isolated Cav1.3−/−/Cav3.1−/− pacemaker cells were automaticity arrested in 5/9 cells tested, or was reduced by 80% in 4/9 cells.

Conclusion

Heart automaticity is primarily generated by Cav1.3 and f-HCN channels. RyR-dependent Ca2+ release cannot sustain automaticity following concomitant targeting of Cav1.3 and f-HCN channels.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 10 - N° 2

P. 238 - aprile 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Transmitral inflow pattern predicts occult paroxysmal atrial fibrillation in the acute phase of ischemic stroke or transient ischemic attack
  • C. Bergerot, A. Py, S. Chauveau, L. Mechtouff, D. Maucort-Boulch, N. Nighoghossian, M. Ovize, H. Thibault
| Articolo seguente Articolo seguente
  • His-Purkinje system defects induced by Nkx2-5 deletion leads to progressive conduction defects and heart failure
  • C. Choquet, M. Nguyen, P. Sicard, F. Kober, I. Varlet, S. Richard, M. Bernard, R. Kelly, N. Lalevée, L. Miquerol

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.