Abbonarsi

Perfusion MR imaging at 3-Tesla: Can it predict tumor grade and histologic necrosis rate of musculoskeletal sarcoma? - 11/07/18

Doi : 10.1016/j.diii.2018.02.005 
P.A. Gondim Teixeira a, , A. Renaud b, S. Aubert c, M. Ben Haj Amor b, Y.-M. Robin d, A. Cotten e, L. Ceugnart b
a Department of Imaging, hôpital Central, CHRU de Nancy, 29, avenue du Maréchal-Lattre-de-Tassigny, 54035 Nancy, France 
b Medical Imaging Department, Oscar Lambret Center, Lille Nord University, 3, rue Frédéric-Combemale, 59000 Lille, France 
c Department of Pathology, University Hospital CHRU, University Lille-Nord de France, 59000 Lille, France 
d Department of General Oncology, Oscar Lambret Cancer Center, 59000 Lille, France 
e Centre de consultation et d’imagerie de l’appareil locomoteur (CCIAL), CHRU de Lille, 2, avenue Oscar-Lambret, 59037 Lille cedex France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To identify quantitative perfusion parameters that are best associated with tumor grade and tumor necrosis at magnetic resonance (MR) imaging at 3-Tesla.

Methods

MR perfusion studies of 31 patients with a musculoskeletal sarcoma were retrospectively evaluated by two readers. There were 18 men and 13 women with a mean age of 34.9±24.4 (standard deviation [SD] years) (range: 6–87 years). All patients underwent carcinologic tumor resection less than 3 months after MR imaging. For all patients six perfusion parameters (three semi-quantitative and three permeability parameters) were analyzed. The percentage of tumor necrosis was estimated using MR imaging. Perfusion data were compared between groups of tumors with different grades and necrosis ratios. Interobserver variability was calculated using intraclass correlation coefficient (ICC).

Results

Interobserver variability among the perfusion parameters was good to excellent (ICC: 0.72–0.9). The area under the curve and maximum slope values showed a significant association with the degree of tumor necrosis (P=0.02–0.04). When tumors with low necrosis ratios were compared to those with high ratios the former parameter was 80% lower. In the same groups, the imaging necrosis index was 56.9–59.8% higher in patients with grade 2 necrosis (P=0.01). Extracellular space volume (Ve) was 31.4% to 55.8% lower in tumors with high grade while the backflow constant (Kep) was 33.6% to 40.1%% higher in tumors with high grade.

Conclusion

Semi-quantitative MR perfusion parameters have an excellent reproducibility and are associated with the degree of histologic tumor necrosis in musculoskeletal sarcomas. The utility of permeability parameters for determining tumor grade needs further investigations.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Magnetic resonance imaging (MRI), Perfusion MR imaging, Musculoskeletal sarcoma, Neoplasm grading, Tumor necrosis

Abbreviations : FNCLCC, MSK, INI, ROI, FSE, NEX, FOV, HPF, SPGR, AIF, ICC, EES, CER, AUC, Max Slope, Ktrans, kep, Ve


Mappa


© 2018  Soci showét showé françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 7-8

P. 473-481 - Luglio 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Effect of cannabis and tobacco on emphysema in patients with spontaneous pneumothorax
  • A.M. Ruppert, J. Perrin, A. Khalil, T. Vieira, D. Abou-Chedid, H. Masmoudi, P. Crequit, M. Giol, J. Cadranel, J. Assouad, V. Gounant
| Articolo seguente Articolo seguente
  • Reduction of patient radiation dose with a new organ based dose modulation technique for thoraco-abdominopelvic computed tomography (CT) (Liver dose right index)
  • M. Fillon, S. Si-Mohamed, P. Coulon, A. Vuillod, P. Klahr, L. Boussel

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.