Background and Aims

ERCP has the risk of exposure to ionizing radiation. Performers may unconsciously increase fluoroscopy time (FT) because of a lack of radiation protection awareness. This study investigates whether a flashing warning light adopted as a behavioral intervention for performers reduces FT and radiation exposure during ERCP.

Methods

We conducted a prospective randomized trial of 200 therapeutic ERCPs. A flashing warning light was placed on top of the endoscopy monitor. Cases were consecutively enrolled and randomly assigned to 2 groups in a 1:1 ratio. In the warning light group, the light was on when the fluoroscopy foot pedal was depressed; in the control group, the light was off. Fluoroscopy and procedure-related data were recorded.

Results

The median FT and dose-area product (DAP) for the warning light group versus the control group were 142.5 seconds versus 175.0 seconds (P = .045) and 856.8 μGy∙m2 versus 1054.4 μGy∙m2 (P = .043). In a multivariable analysis, the use of the warning light was found to reduce FT by 15.4% (–27.0 seconds; P = .042). DAP reduction because of the decreased FT was 15.2% (160.3 μGy∙m2). The reduction in patient effective dose per case was .42 mSv, equivalent to 21 chest radiographs. No adverse events or interference with the procedures because of the warning light were noted.

Conclusions

The use of a flashing warning light is a feasible way to reduce FT and radiation exposure during ERCP. (Clinical trial registration number: ChiCTR-IPR-14005349.)

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : DAP, FT


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2018  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 88 - N° 2

P. 261-266 - agosto 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Water-pocket endoscopic submucosal dissection for superficial gastric neoplasms (with video)
  • Hideaki Harada, Daisuke Murakami, Satoshi Suehiro, Ryotaro Nakahara, Tetsuro Ujihara, Ryota Sagami, Yasushi Katsuyama, Kenji Hayasaka, Yuji Amano
| Articolo seguente Articolo seguente
  • Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis
  • Yen-I Chen, Alan N. Barkun, Viviane Adam, Ge Bai, Vikesh K. Singh, Majidah Bukhari, Olaya Brewer Gutierrez, B. Joseph Elmunzer, Robert Moran, Lea Fayad, Mohamad El Zein, Vivek Kumbhari, Alessandro Repici, Mouen A. Khashab

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.