Abbonarsi

A phase III study evaluating the efficacy and safety of remimazolam (CNS 7056) compared with placebo and midazolam in patients undergoing colonoscopy - 15/08/18

Doi : 10.1016/j.gie.2018.04.2351 
Douglas K. Rex, MD 1, , Raj Bhandari, MD 2, Taddese Desta, MD 3, Michael P. DeMicco, MD 4, Cynthia Schaeffer, MD 5, Kyle Etzkorn, MD 6, Charles F. Barish, MD 7, Ronald Pruitt, MD 8, Brooks D. Cash, MD 9, Daniel Quirk, MD 10, Felix Tiongco, MD 11, Shelby Sullivan, MD 12, David Bernstein, MD 13
1 Indiana University School of Medicine, Indianapolis, Indianapolis 
2 Delta Research Partners, Monroe, Louisiana 
3 Precision Research Institute, San Diego 
4 Advanced Clinical Research Institute, Anaheim 
5 Precision Research Institute, Chula Vista, California 
6 Borland-Groover Clinic, Jacksonville, Florida 
7 Wake Research Associates, Raleigh, North Carolina 
8 Nashville Medical Research Institute, Nashville, Tennessee 
9 University of South Alabama, Mobile, Alabama 
10 Thomas Jefferson Medical College, Philadelphia, Pennsylvania 
11 Gastroenterology Associates of Tidewater, Chesapeake, Virginia 
12 Department of Medicine, University of Colorado, Denver, Colorado 
13 Hofstra Northwell School of Medicine, Hempstead, New York 

Reprint requests: Douglas K. Rex, MD, Indiana University Hospital, 4100, 550 North University Boulevard, Indianapolis, IN 46202.Indiana University Hospital4100, 550 North University BoulevardIndianapolisIN46202

Abstract

Background and Aims

Remimazolam is an ultrashort-acting benzodiazepine.

Methods

We performed a randomized double-blind comparison of remimazolam to placebo for outpatient colonoscopy. This study design was a requirement of the U.S. Food and Drug Administration. An additional group was randomized to open-label midazolam administered according to its package insert instructions (the randomization ratio for remimazolam:placebo:midazolam was 30:6:10). Study medications were administered under the supervision of the endoscopist, without any involvement of an anesthesia specialist. Patients were given 50 to 75 μg of fentanyl before receiving study medications. Patients who failed to achieve adequate sedation in any arm were rescued with midazolam dosed at the investigator’s discretion. The primary endpoint was a composite that required 3 criteria be met: completion of the colonoscopy, no need for rescue medication, and ≤5 doses of remimazolam or placebo in any 15-minute interval (≤3 doses of midazolam in any 12-minute interval in the open-label midazolam arm).

Results

There were 461 randomized patients in 12 U.S. sites. The primary endpoint was met for remimazolam, placebo, and midazolam in 91.3%, 1.7%, and 25.2% of patients, respectively (P < .0001 for remimazolam vs placebo). Patients administered remimazolam received less fentanyl, had faster recovery of neuropsychiatric function, were ready for discharge earlier, and felt back to normal sooner than patients with both placebo and midazolam. Hypotension was less frequent with remimazolam, and hypoxia occurred in 1% of patients with remimazolam or midazolam. There were no treatment-emergent serious adverse events.

Conclusion

Remimazolam can be administered safely under the supervision of endoscopists for outpatient colonoscopy, and it allows faster recovery of neuropsychiatric function compared with placebo (midazolam rescue) and midazolam. (Clinical trial registration number: NCT02290873.)

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract




Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : BP, FDA, HVLT-R, MOAA/S, SpO2, VAS


Mappa


 DISCLOSURE: PAION UK Limited participated in the study design, funded the study, performed the statistical analyses, prepared data tables and figures, and reviewed the manuscript for content and accuracy. B. Cash and D. Bernstein are consultants and advisors for PAION. D. Quirk is a Senior Medical Director at Pfizer. All other authors disclosed no financial relationships relevant to this publication.


© 2018  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 88 - N° 3

P. 427 - settembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Screening for esophageal squamous cell carcinoma: recent advances
  • Don C. Codipilly, Yi Qin, Sanford M. Dawsey, John Kisiel, Mark Topazian, David Ahlquist, Prasad G. Iyer
| Articolo seguente Articolo seguente
  • Multifocal nitrous oxide cryoballoon ablation with or without EMR for treatment of neoplastic Barrett’s esophagus (with video)
  • Marcia Irene Canto, Nicholas J. Shaheen, Jose Alejandro Almario, Lysandra Voltaggio, Elizabeth Montgomery, Charles J. Lightdale

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.