Abbonarsi

Can three-dimensional pelvimetry using low-dose stereoradiography replace low-dose CT pelvimetry? - 17/09/18

Doi : 10.1016/j.diii.2018.02.008 
S. Aubry a, b, , P. Padoin a, Y. Petegnief c, C. Vidal d, D. Riethmuller e, E. Delabrousse b, f
a Department of Musculoskeletal Imaging, CHRU Besançon, 25000 Besançon, France 
b Nanomedecine Laboratory, INSERM EA4662, University of Franche-Comte, 25000 Besançon, France 
c Department of Nuclear Medicine, CHRU Besançon, 25000 Besançon, France 
d Clinical Investigation Center, Inserm CIT808, CHRU Besançon, 25000 Besançon, France 
e Department of Obstetrics and Gynecology, CHRU Besançon, 25000 Besançon, France 
f Department of Abdominal Imaging, CHRU Besançon, 25000 Besançon, France 

Corresponding author. Department of Musculoskeletal Imaging, CHRU Besançon, 25030 Besançon cedex, France.Department of Musculoskeletal Imaging, CHRU Besançon, 25030 Besançon cedex, France.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To evaluate the reliability of pelvimetric measurements performed using stereoradiographic imaging (SRI), and to assess maternal and fetal radiation doses compared to low-dose computer tomography (CT) pelvimetry.

Materials and methods

Thirty-five pregnant women (mean age, 29.6±5.5 [SD] years; range: 20–41 years) were prospectively included. All women underwent simultaneous frontal and lateral low-dose SRI and low-dose CT examination of the pelvis. Pelvimetry measurements were obtained from both examinations and radiation doses obtained with the two techniques were compared.

Results

SRI-CT correlation (Pearson coefficient correlation [r]; mean bias [mb]) was strong for transverse inlet diameter (r=0.92; mb=−0.09cm), anteroposterior diameter of the pelvic inlet (r=0.92; mb = 0.47cm), maximal transverse diameter (r=0.9; mb=0.21cm), sacrum length (r=0.9; mb=0.09cm). Correlation was good. Correlation was good for the sacrum depth (r=0.75; mb=0.06cm) and Magnin's index (r=0.7; mb=0.5cm). Correlation was moderate for anteroposterior diameter of pelvic outlet (r=0.6; mb=0.52cm). The fetal dose was 13.1 times lower using SRI (87±26μGy) than CT (1140±220μGy, P<0.0001). The effective maternal dose was 3.1 times lower using SRI (97±21μSv) than CT (310±60μSv; P<0.0001).

Conclusion

Pelvic inlet measurements using SRI are reliable. Compared to CT pelvimetry, SRI leads to a significant decrease in fetal and maternal radiation doses. These findings should prompt physicians to use SRI as the first-line approach for pelvimetry.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Pelvimetry, Computed tomography (CT), Low-dose stereoradiographic imaging, Radiation dose evaluation, Technology assessment


Mappa


© 2018  Soci showét showé françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 9

P. 569-576 - settembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Lower extremity CT angiography at 80 kVp using iterative model reconstruction
  • B. Liu, S. Gao, Z. Chang, C. Wang, Z. Liu, J. Zheng
| Articolo seguente Articolo seguente
  • Comment on "Shear wave elastography safety in fetus: A quantitative health risk assessment"
  • N. Mottet, R. Ramanah

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.