Abbonarsi

Low-level troponin elevations following a reduced troponin I cutoff: Increased resource utilization without improved outcomes - 18/09/18

Doi : 10.1016/j.ajem.2018.02.001 
Brent A. Becker , Barbara A. Stahlman, Nathaniel McLean, Erik I. Kochert
 Wellspan York Hospital, Department of Emergency Medicine, 1001 S George Street, York, PA 17403, United States 

Corresponding author.

Abstract

Objective

The study sought to evaluate changes in mortality and resource utilization in patients with low level troponin elevations following a reduction in the cutoff for normal troponin I (TnI) from 0.5 ng/mL to the 99th percentile (0.06 ng/mL).

Methods

This was an interrupted time series comparing emergency department (ED) patients with possible acute coronary syndrome (ACS) and TnI values 0.06–0.5 ng/mL before and after an institutional decrease in the TnI cutoff. The primary outcome was overall mortality at 90 days. Secondary outcomes included rates of rehospitalization, subsequent ACS, and coronary intervention within 90 days, as well as rates of anticoagulation, cardiology consultation, cardiac testing, and coronary intervention during the index visit. Outcomes for the pre-cutoff change group (control) and post-cutoff change group (post) were compared using tests of proportions and odds ratios.

Results

The study included a total of 1058 subjects with 529 in each cohort. No significant differences in 90 day outcomes were observed between groups, including mortality (13.2% post vs 14.1% control, OR 0.93 [95% CI: 0.65–1.34], p = 0.705). During the index visit, the post-group demonstrated higher rates of cardiology consultation (55.4% vs 41.2%, OR 1.77 [1.39–2.26], p < 0.0001) and cardiac stress testing (16.4% vs 10.6%, OR 1.66 [1.16–2.38], p = 0.006), but no significant differences in coronary intervention or short-term mortality were observed.

Conclusion

A reduction in the TnI cutoff to the 99th percentile did not change mortality or rates of coronary intervention in ED patients with low level troponin elevations, but significantly increased the use of cardiology resources.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Troponin I, Acute coronary syndrome, Cardiology, Emergency department


Mappa


 Conflicts of Interest/Funding/Disclosures: None.
Prior Presentations:
1.
SAEM Mid-Atlantic Regional Meeting; Philadelphia, PA (February 2014).
2.
SAEM Annual Meeting; Dallas, TX (April 2014).



© 2018  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 36 - N° 10

P. 1810-1816 - ottobre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Intubation of prehospital patients with curved laryngoscope blade is more successful than with straight blade
  • Scott M. Alter, Eithan D. Haim, Alex H. Sullivan, Lisa M. Clayton
| Articolo seguente Articolo seguente
  • High dose insulin for beta-blocker and calcium channel-blocker poisoning
  • Jon B. Cole, Ann M. Arens, JoAn R. Laes, Lauren R. Klein, Stacey A. Bangh, Travis D. Olives

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.