Abbonarsi

Tethered capsule endomicroscopy for microscopic imaging of the esophagus, stomach, and duodenum without sedation in humans (with video) - 10/10/18

Doi : 10.1016/j.gie.2018.07.009 
Michalina J. Gora, PhD 1, 2, Lucille Quénéhervé, MD 2, 3, Robert W. Carruth, MSc 2, Weina Lu, MSc 2, Mireille Rosenberg, PhD 2, 4, Jenny S. Sauk, MD 5, Alessio Fasano, MD 6, Gregory Y. Lauwers, MD 7, Norman S. Nishioka, MD 2, 5, 8, Guillermo J. Tearney, MD, PhD 2, 4, 7, 8, 9,
1 ICube Laboratory, CNRS, Strasbourg University, Strasbourg, France 
2 Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts, USA 
3 Institut des Maladies de l’Appareil Digestif, IMAD, CHU Nantes, Hopital Hôtel-Dieu, Nantes, France 
4 Harvard Medical School, Boston, Massachusetts, USA 
5 Department of Gastroenterology, Massachusetts General Hospital, Boston, Massachusetts, USA 
6 Department of Pediatrics, Massachusetts General Hospital, Boston, Massachusetts, USA 
7 Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts, USA 
8 Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA 
9 Harvard-MIT Division of Health Sciences Technology, Cambridge, Massachusetts, USA 

Reprint requests: Guillermo Tearney, MD, PhD, 55 Fruit Street, BHX604A, Boston, MA 02114.55 Fruit StreetBHX604ABostonMA02114

Abstract

Background and Aims

Patients with many different digestive diseases undergo repeated EGDs throughout their lives. Tethered capsule endomicroscopy (TCE) is a less-invasive method for obtaining high-resolution images of the GI mucosa for diagnosis and treatment planning of GI tract diseases. In this article, we present our results from a single-center study aimed at testing the safety and feasibility of TCE for imaging the esophagus, stomach, and duodenum.

Methods

After being swallowed by a participant without sedation, the tethered capsule obtains cross-sectional, 10 μm–resolution, optical coherence tomography images as the device traverses the alimentary tract. After imaging, the device is withdrawn through the mouth, disinfected, and reused. Safety and feasibility of TCE were tested, focusing on imaging the esophagus of healthy volunteers and patients with Barrett’s esophagus (BE) and the duodenum of healthy volunteers. Images were compared with endoscopy and histopathology findings when available.

Results

Thirty-eight patients were enrolled. No adverse effects were reported. The TCE device swallowing rate was 34 of 38 (89%). The appearance of a physiologic upper GI wall, including its microscopic pathology, was visualized with a tissue coverage of 85.4% ± 14.9% and 90.3% ± 6.8% in the esophagus of BE patients with and without endoscopic evidence of a hiatal hernia, respectively, as well as 84.8% ± 7.4% in the duodenum. A blinded comparison of TCE and endoscopic BE measurements showed a strong to very strong correlation (r = 0.7-0.83; P < .05) for circumferential extent and a strong correlation (r = 0.77-0.78; P < .01) for maximum extent (Prague classification). TCE interobserver correlation was very strong, at r = 0.92 and r = 0.84 (P < .01), for Prague classification circumferential (C) and maximal (M) length measurements, respectively.

Conclusions

TCE is a safe and feasible procedure for obtaining high-resolution microscopic images of the upper GI tract without endoscopic assistance or sedation.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract




Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : BE, MGH, OCT, TCE


Mappa


 DISCLOSURE: This work was supported in part by U.S. National Institutes of Health grants NIH R01CA103769 (G.J.T.) and 1 R01 DK100569-01A1 (G.J.T.). John and Dottie Remondi (G.J.T.) and the MGH Research Scholars program (G.J.T.) provided funding (G.J.T.). L. Quénéhervé received funding from the DHU2020, the DHU Oncogreffe, and the SantéDige Foundation. M. Gora, J. Sauk, N. Nishioka, and G. Tearney, have the rights to receive royalties as part of a licensing arrangement between NinePoint Medical and Massachusetts General Hospital. G. Tearney is a consultant for NinePoint Medical and receives sponsored research from iLumen and Boston Scientific. All other authors disclosed no financial relationships relevant to this article.
 If you would like to chat with an author of this article, you may contact Dr Tearney at gtearney@partners.org.


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 88 - N° 5

P. 830 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Is 35 the new 50? Challenges in determining colonoscopy surveillance recommendations for young patients with incidentally detected adenomas
  • Karla Cameron, Alan Moss
| Articolo seguente Articolo seguente
  • Long-term recurrent bleeding risk after endoscopic therapy for definitive colonic diverticular bleeding: band ligation versus clipping
  • Naoyoshi Nagata, Naoki Ishii, Mitsuru Kaise, Takuro Shimbo, Toshiyuki Sakurai, Junichi Akiyama, Naomi Uemura

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.