Abbonarsi

Sonographic diameter of optic nerve sheath in differentiation of ischemic and hemorrhagic strokes; a diagnostic accuracy study - 15/10/18

Doi : 10.1016/j.ajem.2018.08.041 
Mohammad Manouchehrifar a, Masoumeh Lakestani a, Parvin Kashani a, Saeed Safari b,
a Emergency Department, Loghmane Hakim Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran 
b Emergency Department, Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran 

Corresponding author at: Emergency Department, Shohadaye Tajrish Hospital, Shahrdari Avenue, Tajrish Square, Tehran, Iran.Emergency DepartmentShohadaye Tajrish HospitalShahrdari AvenueTajrish SquareTehranIran

Abstract

Introduction

Differentiating between ischemic and hemorrhagic types is of special importance in the treatment process of patients with stroke. The present study was designed with the aim of evaluating the diagnostic accuracy of ultrasonographic optic nerve sheath diameter (ONSD) in differentiation of ischemic from hemorrhagic stroke.

Methods

The present research is a diagnostic accuracy study on patients with stroke presenting to emergency department during 1 year. Ultrasonographic diameter of optic nerve sheath of both eyes was measured for all the patients and its sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios in differentiating ischemic stroke from hemorrhagic type were calculated considering CT scan findings as the gold standard.

Results

80 patients with stroke (40 hemorrhagic and 40 ischemic) were studied. Mean age of the patients was 65.0 ± 13.1 years (57.5% male). Mean ONSD was 5.5 ± 0.4 mm in the ischemic group and 6.1 ± 0.7 mm in the hemorrhagic group (p < 0.0001). Area under the curve of ONSD in differentiation of hemorrhagic and ischemic stroke was 0.75 (95% CI: 0.64–0.86). In 5.5 mm cut-off point, sensitivity and specificity of ONSD in identifying the type of stroke were 75.0% (95% CI: 58.5–86.8) and 52.5% (95% CI: 36.3–68.2), respectively. These values were 57.5% (95% CI: 41.0–68.2) and 90.0% (95% CI: 75.4–96.7), respectively, in the 6 mm cut-off point.

Conclusion

Findings of the present study showed that ultrasonographic diameter of optic nerve sheath has moderate accuracy in differentiation of hemorrhagic and ischemic stroke.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Stroke, Optic nerve, Diagnosis, differential, Diagnostic imaging, Ultrasonography, Tomography, X-ray computed, Intracranial hypertension


Mappa


© 2018  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 36 - N° 11

P. 2064-2067 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Diagnostic accuracy of a rapid telemedicine encounter in the Emergency Department
  • Joseph A. Izzo, Jonathan Watson, Rahul Bhat, Matthew Wilson, Joseph Blumenthal, Christina Houser, Edward Descallar, Daniel Hoffman, Ethan Booker
| Articolo seguente Articolo seguente
  • First-presentation with psychotic behavior to the Emergency Department: Meningitis or not, that is the question
  • Abdullah E. Laher, Yousef Etlouba, Muhammed Moolla, Feroza Motara, Nazeema Ariefdien

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.