Abbonarsi

Assessing 3D paediatric foot morphology using low-dose biplanar radiography: Parameter reproducibility and preliminary values - 29/10/18

Doi : 10.1016/j.otsr.2018.07.023 
Virginie Rampal a, b, , Pierre-Yves Rohan a, Rebekah Saksik a, Philippe Wicart c, Wafa Skalli a
a Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, 151, boulevard de l’hôpital, 75013 Paris, France 
b Service d’orthopédie pédiatrique, hôpitaux pédiatriques de Nice CHU Lenval, 57, avenue de la Californie, 06000 Nice, France 
c Service d’orthopédie pédiatrique, Hôpital Necker-Enfants Malades, 149, rue de Sèvres, 75015 Paris, France 

Corresponding author. Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, 151, boulevard de l’hôpital, 75013 Paris, France.Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech151, boulevard de l’hôpitalParis75013France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

The physical examination and weight-bearing radiography are the two main available methods for assessing the feet and lower limbs. The anatomy and function of these two structures interact with each other. These two assessment methods are affected by subjectivity and projection bias. Low-dose biplanar radiography (LDBR) is now a promising alternative for evaluating the lower limbs in children. At present, however, the foot cannot be assessed using LDBR. The objective of this study was to work towards developing a new method for 3D radiographic analysis of the paediatric foot during weight-bearing, first by determining the reproducibility of landmarks defined by LDBR then by reporting the values of the calculated radiographic parameters.

Hypothesis

A new radiographic method based on LDBR can be used to obtain a 3D evaluation of the foot in paediatric patients.

Patients and methods

Two biplanar radiographs in perpendicular planes were obtained simultaneously in a standardised position using the EOS system (EOS® Imaging, Paris, France) in each of 10 healthy children. To assess measurement uncertainty, two observers performed 3D reconstructions of each of the 10 feet three times (60 reconstructions). The standard error of reproducibility of the anatomic landmarks and clinical parameters was computed. Measurement uncertainty was then estimated based on the 95% confidence interval (95%CI). To obtain reference values, the mean±SD of each variable was computed after checking that the data were normally distributed.

Results

Reproducibility was high for the anatomical landmarks of interest, calcaneal pitch angle, tibio-calcaneal angle on the lateral view, and first metatarsal pitch angle (95%CI<5%). The values of these angles in the study population are reported.

Discussion and conclusion

The data reported here pave the way towards developing new parameters for describing 3D foot morphology and for simultaneously assessing the lower limb and foot in the standing position.

Level of evidence

I.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Foot, Stereoradiography, Reproducibility, Parameter values, Standing position, Paediatric patient


Mappa


© 2018  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 7

P. 1083-1089 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Can Gartland II and III supracondylar humerus fractures be treated using Blount's method in the emergency room?
  • Jonathan Thomas, Olivier Rosello, Ioana Oborocianu, Federico Solla, Jean-Luc Clement, Virginie Rampal
| Articolo seguente Articolo seguente
  • Outpatient paediatric arthroscopy: A retrospective study in 216 Patients
  • Walid Lakhal, Kitisack Chanthany, Laurent Bund, Ludovic Schneider, Philippe Gicquel

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.