Abbonarsi

Precise Cobb Angle Measurement System Based on Spinal Images Merging Function - 04/11/18

Doi : 10.1016/j.irbm.2018.09.002 
S. Lee a, J.S. Lee b, J.P. Kim c, K. Kim d, C.H. Hwang e, , K.-i. Koo a,
a Department of Biomedical Engineering, University of Ulsan, Ulsan, Republic of Korea 
b Department of Orthopedic Surgery, School of Medicine, Pusan National University Hospital, Pusan, Republic of Korea 
c Mobile Healthcare Laboratory, Samsung Advanced Institute of Technology, Suwon, Republic of Korea 
d Department of Electronics and Control Engineering, Hanbat National University, Daejeon, Republic of Korea 
e Department of Physical Medicine and Rehabilitation, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea 

Corresponding authors.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 10
Iconografia 14
Video 0
Altro 0

Abstract

Background

Convenient and precise measurement of the Cobb angle using a small size X-ray detector has been required for local clinics.

Methods

Cobb angle measurement system using a conventional X-ray source and detector is proposed for accurate Cobb angle measurement. The system consists of a conventional X-ray source, a ruler-added X-ray table, a conventional X-ray detector, and an image processing program. The X-ray table has the lead ruler patterns. The patterns remain white ruler patterns on X-ray images. The proposed image processing program merges the three spinal X-ray images into one whole spinal X-ray image by detecting the ruler patterns on the three spinal X-ray images.

Results

In order to evaluate our program, Cobb angle measured in the merged image is compared with Cobb angle measured in the X-ray image taken by a large X-ray detector. Average of difference between them is 2.251 degree and standard deviation is 1.339.

Conclusion

The developed measurement system demonstrated its measurement performance accurately and practically.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

Precise Cobb angle measurement system consists of three parts.
A ruler-added table, an image processing program, a typical X-ray imaging system.
The table has the lead ruler patterns to remain white ruler patterns on X-ray images.
The proposed program merges the three spinal images into one whole spinal image.
This merging enables to measure the Cobb angle precisely.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2018  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 39 - N° 5

P. 343-352 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • An Optimized Cascaded Stochastic Resonance for the Enhancement of Brain MRI
  • M. Singh, A. Verma, N. Sharma
| Articolo seguente Articolo seguente
  • Early Stage Chronic Kidney Disease Diagnosis by Applying Data Mining Methods to Urinalysis, Blood Analysis and Disease History
  • S.B. Akben

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.