Abbonarsi

Microwave Resonant Sensor for Non-invasive Characterization of Biological Tissues - 23/11/18

Doi : 10.1016/j.irbm.2018.10.013 
M. Tlili a , F. Deshours a, , G. Alquié a , H. Kokabi a , S. Hardinata a , F. Koskas b
a Sorbonne Université, Laboratoire d'Électronique et Électromagnétisme, L2E, F-75005 Paris, France 
b Sorbonne Université, AP-HP, Hôpital Pitié-Salpêtrière, Service de chirurgie vasculaire, F-75005 Paris, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 6
Iconografia 9
Video 0
Altro 0

Abstract

Context

Microwave sensing appears to be an open wide field to investigate medical applications, such as monitoring of vital signs (temperature, arterial pressure, …), following different kinds of pathologies (cancer, glucose level …) and aid for medical diagnosis. It offers an alternative to determine the dielectric properties of biological tissues through the development of local non-invasive and/or embedded sensors, giving thus a kind of imaging by the dielectric contrast. Moreover, RF communications links between several sensors can be developed to realize “Body Area Networks”.

Methods

Biological tissues having high dielectric permittivity and losses in the microwave frequency domain (around 1 GHz), a resonant dielectric characterization method is used to obtain a good sensitivity. The experimental setup is based on the measured changes of electrical characteristics of the resonator (resonance frequency and its shift and broadening) when a biological tissue is applied on it. In our case, the sensor is a microstrip ring resonator operating in a two-port configuration at a fundamental frequency of 1 GHz. It consists of a meander loop in order to reduce its dimensions. Besides, an original excitation is proposed leading to small perturbation of the resonator when high dielectric losses material is characterized. This increased greatly the sensitivity of the method to obtain the dielectric properties of the samples. Dielectric parameters are determined by fitting S parameters measurements results with those of simulations using electromagnetic software's (HFSS, CST).

Results

Several biological tissues of animal origin were measured ex-vivo in the frequency range 0.5–5 GHz. The dielectric parameters obtained by this method are consistent with values proposed in databases or obtained by other researchers. A very good agreement between simulations and measurements is obtained leading to a good extraction of permittivity and losses of the tissues.

Conclusions

This paper presents an improved microwave sensor, either for reduced dimensions as for sensitivity, able to perform dielectric characterization of material having high complex permittivity such as biological tissues. Experiments and electromagnetic simulations have been achieved on several animal tissues (chicken, beef, pork …), and results are in good agreement with literature. Works are in progress to optimize this sensor as an applicator for medical applications.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

A ring resonator for non-invasive microwave dielectric characterization is proposed.
A CPW feeding structure is investigated to provide better coupling.
The distributed resonator has been miniaturized with a meander shape.
The sensor has a good accuracy even for high dielectric loss materials.
Dielectric parameters of several animal biological tissues have been extracted by ex-vivo measurements.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Dielectric measurements, Microwave sensor, Ring resonator, Biological tissues


Mappa


© 2018  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 39 - N° 6

P. 445-450 - dicembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Serious Games for Home Based Rehabilitation: Inertial Sensor Energy Consumption
  • H. Tannous, D. Istrate, A. Benlarbi-Delai, J. Sarrazin, M.-C. Ho Ba Tho, T.T. Dao

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.