Breast mass characterization using shear wave elastography and ultrasound - 19/12/18

Doi : 10.1016/j.diii.2018.06.002 
S. Hari a, S.B. Paul a, , R. Vidyasagar a, E. Dhamija a, A.D. Adarsh a, S. Thulkar a, S. Mathur b, V. Sreenivas c, S. Sharma a, A. Srivastava d, V. Seenu d, R. Prashad d
a Department of Radiology, All India Institute of Medical Sciences, 110029 New Delhi, India 
b Departments of Pathology, All India Institute of Medical Sciences, 110029 New Delhi, India 
c Departments of Biostatistics, All India Institute of Medical Sciences, 110029 New Delhi, India 
d Departments of Surgery, All India Institute of Medical Sciences, 110029 New Delhi, India 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To evaluate the role of SWE in characterizing breast masses and ascertain whether additional use of SWE to ultrasound for evaluating BI-RADS 3 and 4a masses could help reduce long-term follow-up and unnecessary biopsies of these suspicious breast masses.

Materials and methods

This prospective, cross-sectional study was performed between June 2013 and November 2014. All enrolled patients underwent clinical breast examination, ultrasound, SWE and ultrasound-guided core biopsy of the breast mass. Breast Imaging Reporting and Data System (BI-RAD) categories were assigned to breast masses. For qualitative and quantitative variables of SWE, cut-off values for differentiation between benign and malignant breast masses were estimated. Modified BIRADS’ (up/downgrading of BIRADS category) was done for BI-RADS 3/4a masses by combining individual SWE parameters and ultrasound findings. Sensitivity, specificity, positive and negative predictive value of modified BI-RADS’ and ultrasound BI-RADS were compared.

Results

A total of 119 women (mean age, 42.3±13.6 [SD] years; range: 13–87 years) with a single breast mass each were enrolled. Histopathologically, 57/119 (48%) breast masses were benign and 62 (52%) were malignant. On ultrasound, 42 breast masses were BI-RADS3 and 77 were BI-RADS 4 (4a, n=10; 4b, n=24; 4c, n=43) leading to 96.8% sensitivity and 70.2% specificity. On SWE, benign breast masses were oval/round, homogenous/reasonably homogenous, blue/green with lower elasticity values and malignant breast masses were irregular, inhomogeneous, red/orange with high elasticity values. On modified BI-RADS’ using E-color and E-mean/E-max, specificity improved to 78.9% and 75.4% respectively.

Conclusion

Addition of SWE to ultrasound improves characterization of BI-RADS 3 and 4a masses. E-max, E-mean and E-color are the most useful SWE parameters to differentiate between malignant and benign breast masses.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Shear wave elastography, Ultrasound, Breast mass, Image analysis


Mappa


© 2018  Soci showét showé françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 11

P. 699-707 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Distribution of left ventricular trabeculation across age and gender in 140 healthy Caucasian subjects on MR imaging
  • Z. Bentatou, M. Finas, P. Habert, F. Kober, M. Guye, S. Bricq, A. Lalande, J. Frandon, JN. Dacher, B. Dubourg, G. Habib, J. Caudron, S. Normant, S. Rapacchi, M. Bernard, A. Jacquier
| Articolo seguente Articolo seguente
  • Artificial intelligence assistance for fetal head biometry: Assessment of automated measurement software
  • G. Ambroise Grandjean, G. Hossu, C. Bertholdt, P. Noble, O. Morel, G. Grangé

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.