Abstract

Purpose

The purpose of this study was to report the incidence of massive bleeding after endoscopic ultrasound-guided transmural pancreaticobiliary drainage (EUS-TPBD) and the clinical outcomes in patients with this condition treated with transcatheter arterial embolization (TAE).

Patients and methods

We performed a 9-year retrospective analysis of 797 EUS-TPBD procedures (excluding gallbladder or pseudocysts) in 729 patients. Among them, twelve (12/729, 1.65%) patients were referred for TAE to manage active bleeding adjacent to the TPBD sites. There were 8 men and 4 women with a mean age of 66.1 years±13.4 (SD) (range: 45–89 years). The clinical and procedure data of these 12 patients were reviewed.

Results

Thirteen TAE procedures in 12 patients were performed. The bleeding sites were the left hepatic artery (n=7), the right hepatic artery (n=3), the left gastric artery (n=1), the left accessory gastric artery (n=1) and gastroduodenal artery (n=1). TAE was performed with gelatin sponge particles (n=1), coil (n=1) and n-butyl-2 cyanoacrylate with/without coils (n=11), with technical and clinical success rates of 100% (13/13) and 85% (11/13), respectively. Re-bleeding following embolization with gelatin sponge particles occurred in one patient. Procedure-related ischemic hepatitis was observed in another patient with pancreatic cancer with portal vein involvement.

Conclusion

On the basis of our results, TAE using n-butyl-2 cyanoacrylate seems safe and effective for the treatment of bleeding after EUS-TPBD procedures. When the portal vein is compromised, TAE of the hepatic artery can cause ischemic liver damage.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Endoscopic ultrasonography, Therapeutic arterial embolization (TAE), Gastrointestinal hemorrhage


Mappa


 This study was accepted and presented as a poster presentation at CIRSE 2015.


© 2018  Soci showét showé françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 11

P. 717-724 - Novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Artificial intelligence assistance for fetal head biometry: Assessment of automated measurement software
  • G. Ambroise Grandjean, G. Hossu, C. Bertholdt, P. Noble, O. Morel, G. Grangé
| Articolo seguente Articolo seguente
  • MR imaging of cystic ovarian teratoma with internal floating globules
  • J. Zeitoun, C. Escalard, G. Benoist

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.