Abbonarsi

Randomized Controlled Trial Comparing White Light with Near-Infrared Autofluorescence for Parathyroid Gland Identification During Total Thyroidectomy - 25/04/19

Doi : 10.1016/j.jamcollsurg.2018.12.044 
Fernando Dip, MD, FACS a, c, , Jorge Falco, MD, FACS a, Silvina Verna, MD a, Marcos Prunello, MD b, Matias Loccisano, MD a, Pablo Quadri, MD a, Kevin White, MD, PhD d, Raul Rosenthal, MD, FACS c
a Instituto Argentino de Diagnóstico y Tratamiento, Buenos Aires, Argentina 
b Department of Surgery, Universidad Nacional de Rosario, Rosario, Argentina 
c Section of Minimally Invasive Surgery, Department of General Surgery, Cleveland Clinic Florida, Weston, FL 
d ScienceRight Research Consultations, London, Ontario, Canada 

Correspondence address: Fernando Dip, MD, FACS, Instituto Argentino de Diagnostico y Trataminto, Marcelo Torcuato de Alvear 2346/2400, C1122 CABA, Buenos Aires, Argentina.Instituto Argentino de Diagnostico y TratamintoMarcelo Torcuato de Alvear 2346/2400CABA, Buenos AiresC1122Argentina

Abstract

Background

Parathyroid glands are difficult to identify during total thyroidectomies, and accidental resection can lead to problematic postoperative hypocalcemia. Our main goals were to evaluate the effectiveness of using near-infrared light (NIRL) autofluorescence intraoperatively for parathyroid gland identification and to measure its impact on postoperative hypocalcemia incidence.

Study Design

Total thyroidectomies were performed on 170 patients with different thyroid pathologies, block-randomized (1:1) into 2 equal groups. Among controls, traditional overhead white light (WL) was used throughout. In the experimental group, NIRL was used to enhance parathyroid gland recognition before thyroid dissection. The number of parathyroid glands identified was compared after thyroid dissection in controls using WL vs pre-dissection in the experimental using NIRL and with WL vs NIRL before thyroid dissection in the experimental group. Postoperative serum calcium levels and hypocalcemia rates were compared.

Results

The mean number of parathyroid glands identified pre-dissection with NIRL was the same identified post-dissection with WL (3.5 vs 3.6). In the experimental group, converting from WL to NIRL increased the number of glands detected from 2.6 to 3.5 (p < 0.001), and revealed at least 1 previously missed gland in 67.1% of patients. Calcium levels ≤7.5 mg/dL were one-tenth as common in the NIRL group (p = 0.005). The adjusted odds of hypocalcemia developing increased by 15% for every 5-g increase in thyroid gland weight (odds ratio 1.15; 95% CI 1.06 to 1.25). All hypocalcemia resolved within 6 months.

Conclusions

Using NIRL during thyroidectomy increases intraoperative identification of parathyroid glands, enhances their detection before thyroid dissection, and decreases the incidence of postoperative hypocalcemia.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Disclosure Information: Nothing to disclose.


© 2019  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 228 - N° 5

P. 744-751 - maggio 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Enhancing Parathyroid Gland Visualization Using a Near Infrared Fluorescence-Based Overlay Imaging System
  • Melanie A. McWade, Giju Thomas, John Q. Nguyen, Melinda E. Sanders, Carmen C. Solórzano, Anita Mahadevan-Jansen
| Articolo seguente Articolo seguente
  • Whose Benchmark Is Right? Validating Venous Thromboembolism Events Between Trauma Registries and Hospital Administrative Databases
  • Todd A. Miano, Grigor Abelian, Mark J. Seamon, Kristen Chreiman, Patrick M. Reilly, Niels D. Martin

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.