Abbonarsi

High-Intensity Focused Ultrasound Using a Toroidal Transducer as an Adjuvant Treatment for Placenta Accreta: A Preliminary Ex Vivo Study - 20/07/19

Doi : 10.1016/j.irbm.2019.05.008 
J. Caloone a, b, V. Barrere a, M. Sanchez a, S. Cambronero a, C. Huissoud b, c, d, D. Melodelima a,
a LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France 
b Department of Obstetrics and Gynecology, Croix Rousse University Hospital, Lyon, F-69004, France 
c Stem Cell and Brain Research Institute, Institut National de la Sante et de la Recherche Médicale U846, 18 avenue du Doyen Lepine, Bron, France 
d Université de Lyon, Université Lyon I, 69003 Lyon, France 

Corresponding author at: Laboratory of Therapeutic Applications of Ultrasound – INSERM U1032, 151 cours Albert Thomas, 69003 Lyon, France.Laboratory of Therapeutic Applications of Ultrasound – INSERM U1032151 cours Albert ThomasLyon69003France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 7
Iconografia 5
Video 0
Altro 0

Abstract

Background

Placenta accreta is an abnormal invasion of the placenta within the myometrium, which has increasing rate and could result in maternal mortality or morbidity. The objective of this study was to evaluate the feasibility of treating placenta accreta with high-intensity focused ultrasound (HIFU) using an ex vivo model.

Material and methods

A toroidal HIFU transducer working at 2.5 MHz with an integrated ultrasound-imaging probe was used. Ex vivo experiments were performed in eight human placentae (from 39 to 40 weeks) within a configuration that mimicked clinical conditions as closely as possible. The fetal side of the placenta was placed in contact with the sterile envelope that covered the HIFU device to simulate the uterine serosa. HIFU lesions were studied on sonograms and macroscopically.

Results

In total, 19 single HIFU lesions were created with the same exposure parameters for all of the lesions. The exposure time was 75 s. The acoustic power was 90 W. HIFU lesions were created at different distances (2, 6, 7 and 8 mm) from the uterine serosa by adjusting the thickness of the coupling water and thus, the distance between the HIFU emitters and placental tissues. All of the lesions were homogeneous and approximately spherical in shape. The two diameters of the HIFU lesions were on average   and  . Lesions were immediately visible on sonograms after each HIFU exposure as a hyperechoic region. The distance between the surface of the placenta and HIFU lesion as measured on ultrasound images was closely correlated with the same distance that was measured on gross pathology ( ,  ).

Conclusions

This study demonstrates that HIFU may be an interesting option for adjuvant treatment during a cesarean of placenta accreta. These results must be validated under real clinical conditions.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

A toroidal HIFU transducer can create large lesions in the placenta in short time.
All of the lesions were homogeneous and approximately spherical in shape.
HIFU may be an interesting option for adjuvant treatment of placenta accreta.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : High intensity focused ultrasound, HIFU, Ex vivo, Placenta, Accreta


Mappa


© 2019  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 40 - N° 4

P. 228-234 - agosto 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Recent Trends in Computer Assisted Diagnosis (CAD) System for Breast Cancer Diagnosis Using Histopathological Images
  • C. Kaushal, S. Bhat, D. Koundal, A. Singla
| Articolo seguente Articolo seguente
  • A Modified DWT-SVD Algorithm for T1-w Brain MR Images Contrast Enhancement
  • M. Sahnoun, F. Kallel, M. Dammak, O. Kammoun, C. Mhiri, K. Ben Mahfoudh, A. Ben Hamida

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.