Abbonarsi

Kinematic alignment versus conventional techniques for total hip arthroplasty: A retrospective case control study - 27/08/19

Doi : 10.1016/j.otsr.2019.02.012 
Charles Rivière a, , Ciara Harman b, Thomas Parsons b, Loic Villet c, Justin Cobb d, Cedric Maillot a
a South West London Elective Orthopaedic Centre, MSK Lab – Imperial College London, Dorking Road, KT18 7EG Epsom, United Kingdom 
b SWLEOC Research centre, Dorking Road, KT18 7EG Epsom, United Kingdom 
c Clinique du Sport, Centre de l’arthrose, 4, rue Georges-Negrevergne, 33700 Mérignac, France 
d Laboratory Block, MSK Lab – Imperial College London, Charing Cross Campus, St Dunstan's Road, W6 8RP Hammersmith, London United Kingdom 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Residual complications of conventionally implanted hip components have only been partially reduced by improved implant design and higher surgical precision, and their occurrence is poorly predicted by the radiographic standing/supine cup orientation. This has raised awareness that conventional techniques may not aim for the correct component orientation target, and the lumbo-pelvic kinematics, which influences the functional acetabular orientation, may be of interest to further improve THA clinical outcomes. This has led to the development of the Lumbo-Pelvic kinematic alignment (KA) technique for THA that aims to anatomically position and kinematically align hip implants (acetabular and femoral, total and resurfacing components), in order to optimise prosthetic hip biomechanics and hopefully improve prosthetic function, patient satisfaction, and components’ lifespan. Therefore, we conducted a case control investigation to assess the early-term safety and efficacy of this new technique by answering the following questions: does the KA technique for THA: (1) better restore the native hip anatomy, (2) generate a different radiographic supine cup position, and (3) improve clinical outcomes in comparison to the conventional mechanical alignment technique?

Hypotheses

Using KA technique allows there is no statistically significant difference between the pre to postoperative differential for acetabular medial and vertical offsets, femoral offset, and leg length.

Methods

We led a case control retrospective study with prospectively collected clinical data. Forty-one consecutive unselected KA-THAs performed with manual instrumentation were paired with 41 mechanically aligned THAs. The 1-year clinical outcomes and radiographical measurements were compared.

Results

Compared to the mechanical alignment technique, the KA technique resulted in a more anatomical restoration of the prosthetic hip centre of rotation with a lower delta pre- to post-operative horizontal acetabular offset (1.47mm for KA versus −5.1mm for MA, p=0.001), and with 74% of KA versus 50% of MA cups (p=0.044) being within 15% of native anatomy for the horizontal acetabular offset. In addition, the KA technique resulted in a higher cup anteversion (22°±7° vs 15°±8°, p<0.001) but similar cup inclination (41°±6° vs. 42°±7°, p=0.25), a similar proportion of cups within the Lewinnek zone (65% vs. 70%, p=0.8), similar excellent functional outcomes (delta Oxford score pre- to follow-up of 24.3 and 23.5 points for KA and MA groups, respectively, p=0.88), similar patient satisfaction scores of 95.4/100 and 89.5/100 for KA and MA groups, respectively, and the same absence of aseptic complications.

Conclusion

The KA technique for THA has been demonstrated to be safe, efficacious, and not inferior to the conventional MA technique at early-term. As the concept of the KA technique for THA is only at an early stage, its influence on mid to long-term clinical outcomes remains to be determined and further refinements of the concept are yet to be made.

Level of evidence

III; case-control retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip replacement, Kinematic alignment, Anatomic alignment, Spine-hip relationship, Spine stiffness, Spine kinematics


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 105 - N° 5

P. 895-905 - settembre 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Management of anteromedially displaced acetabular fractures using a collinear reduction clamp through modified ilioinguinal approach
  • Chul-Young Jang, Dae-Kyung Kwak, Hyung-Min Lee, Ji-Hyo Hwang, Je-Hyun Yoo
| Articolo seguente Articolo seguente
  • Modern cup alignment techniques in total hip arthroplasty: A systematic review
  • Cédric Maillot, Ciara Harman, Loïc Villet, Justin Cobb, Charles Rivière

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.