Introduction

In total knee replacement surgery, medio-lateral knee balancing is recognized as the key to achieving satisfactory functional results. But it may not be enough to stabilize the flexion gap using deep-dished implants. We achieved flexion gap balance by oversizing the femoral component, thus increasing the posterior condylar offset (PCO). The purpose of this study was to describe the applicability of this technique and to test whether it produced adverse effects on medium-term outcomes. We hypothesized that it would not compromise the results if used properly. We therefore asked: (1) at how many cases of flexion gap balance would require oversizing the femoral component; (2) if femoral components oversizing would modify the mid-term results as per forgotten joint score (FJS) scores and whether flexion gain would be comparable to patients in whom it was not increased.

Materials and methods

Ninety-four patients (120 knees) were operated between September 2009 and 2011 (age 68±9 years) using the cementless Hyperflex version of the Natural Knees (Zimmer, Warsaw, IN, USA). Postero stabilization was achieved using deep-dished inserts. The Gender configuration has provided narrow inserts to better adapt the female anatomy. A special navigation system measured the displacement of the lateral and medial femoro-tibial contact points with infra-millimetric precision. Adopting a tibial cut first, gap-balancing technique with anterior referencing, the decision to oversize the femoral component relied on the 90° flexion drawer test, which showed more than 6mm sagittal laxity before the femoral bone cuts. Eighty-one (105 knees) patients were reviewed with average 63±27-month follow-up.

Results

Femoral components were augmented by 1 size in 60 cases and by 2 sizes in 7 cases. At final review, knees with an oversized femoral component (60) achieved the same results as those implanted with a non-oversized femoral component (n=45) in terms of mean flexion gain (−5°±34 versus −4°±23, p=0.78), mean FJS (63±26 versus 61±23; p=0.56).

Conclusion

Balancing the Flexion gap by oversizing the femoral component did not compromise flexion range and functional results.

Level of evidence

IV, Retrospective cohort study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Deep-dished total knee replacement, Femoral component size, Sagittal balance, Navigation, Primary total knee replacement


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 105 - N° 6

P. 1039-1045 - ottobre 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Where are we with return-to-sport testing following ACL reconstruction?
  • Julian A. Feller, Kate E. Webster
| Articolo seguente Articolo seguente
  • Same-stage total knee arthroplasty and osteotomy for osteoarthritis with extra-articular deformity. Part I: Tibial osteotomy, prospective study of 26 cases
  • Yves Catonné, Elhadi Sariali, Frédéric Khiami, Jean-Louis Rouvillain, Antony Wajsfisz, Hugues Pascal-Moussellard

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.