Abbonarsi

Validation of an UPLC-MS/MS method for the determination of sixteen synthetic cannabinoids in human hair. Application to document chronic use of JWH-122 following a non-fatal overdose - 06/12/19

Doi : 10.1016/j.toxac.2019.10.005 
Islam Amine Larabi , Mohammed Riffi, Nicolas Fabresse, Isabelle Etting, Jean-Claude Alvarez
 Laboratory of Pharmacology–Toxicology, Raymond-Poincaré Universitary Hospital, Versailles Saint-Quentin-en-Yvelines University, Inserm U-1173, AP–HP, 104, boulevard R. Poincaré, 92380 Garches, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 10
Iconografia 1
Video 0
Altro 0

Summary

Purpose

Synthetic cannabinoids (SCs) are the largest group of new psychoactive substances (NPS) monitored worldwide. We validate a rapid and sensitive liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) assay for the determination of 16 SCs in human hair samples. This method was successfully applied to document chronic use of JWH-122 in a 42 years-old male included in large-scale cross-sectional study in Paris.

Method

The SCs JWH-018, JWH-018-5-N(OH-pentyl), JWH-073, JWH-073-4-N(OH-butyl), JWH-122, JWH-200, JWH-019, JWH-250, AM-2201, EAM-2201, BB-22, ADB-PINACA, AKB48-5F, AB-FUBINACA, 5F-AB-PINACA, 5F-PB-22 were extracted from 20mg of decontaminated, washed and grinded hair by a mixture of hexane/ethyl acetate (1/1, v/v) in alkaline condition in the presence of JWH-018-D11 internal standard. SCs were then separated by a gradient of formate buffer 2mM in 0.1% formic acid (A) and acetonitrile (B) on Hypersyl Gold PFP column (100×2.1mm i.d., particle size 1.9 µm, ThermoFisher) at 30°C. The detection was performed on TSQ Vantage triple-quadrupole mass spectrometer (Thermofisher, Les Ulis, France) in positive ionization and multi-reaction monitoring (MRM) modes. A lock of hair (6cm) was sampled from a patient hospitalized for JWH 122 overdose and segmented into 3 segments: A: 0-2cm (proximal), B: 2-4cm and C: 4-6cm. It was then analyzed with the present method in order to determine past use of synthetic cannabinoids.

Results

The method exhibits a good linearity (r2>0.996) over the range 1-25 to 1000pg/mg, Limits of detection and quantification ranged from 0.3 to 8pg/mg and from 1 to 25pg/mg, respectively (CVs ≤15%). No interference from endogenous substances with the detection of SCs and their IS was observed and the carryover was insignificant. Intraday and inter-day trueness (bias) and precision (CVs) were ≤8.2%, ≤14.3%, ≤8.3% and ≤14.9%, respectively. Overall recoveries ranged between 61 and 94% and corrected matrix effect from 31 to 110%. JWH-122 hair concentrations found in patient's hair were: (A/B/C: 200/450/430pg/mg) in agreement with the concentrations found in the literature suggesting chronic use of JWH-122 over the last six months.

Conclusion

The present LC-MS/MS method proved to be suitable for the detection and quantification of 16 synthetic cannabinoids in human hair.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Synthetic cannabinoids, JWH-122, Hair, Mass spectrometry, New psychoactive substances


Mappa


© 2019  Société Française de Toxicologie Analytique. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 31 - N° 4

P. 283-292 - dicembre 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • GC-MS, GC-QTOF and NMR analyses to elucidate composition of 41 powders from an NPS collector
  • Charline Bottinelli, Kévin Revelut, Maggy Hologne, Yvan Gaillard, Fabien Bévalot
| Articolo seguente Articolo seguente
  • Designer anabolic steroids: A challenge for toxicologists
  • Laurie Gheddar, Alice Ameline, Jean-Sébastien Raul, Pascal Kintz

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.