Mitral valve repair based on intraoperative objective parameters measurement: State of the art and perspective - 06/01/20

Doi : 10.1016/j.acvdsp.2019.09.374 
D. Grinberg 1, 2, , A. Bruhat 3, Jean-François Obadia 1, P.J. Cottinet 2, D. Pandis 4, A. Costa 3, D.H. Adams 4
1 Cardiovascular Surgery at Hôpital Louis Pradel- Lyon Medical School 
2 LFEF - INSA université de Lyon, Lyon, France 
3 Sinai Biodesign Lab at Icahn school of Medicine 
4 Cardiovascular surgery at Mount Sinai Hospital, New York, Etats-Unis 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Riassunto

Background

Currently, mitral valve repair (MVr) success for primary mitral regurgitation relies mainly on surgeon's expertise and major heterogeneities are observe concerning MVr rate, technics, and results. MVr success is estimated by a morphological echocardiographic assessment after aortic unclamping. To date, coaptation forces have been poorly characterized.

Purpose

We developed a device allowing a precise morphologic and qualitative assessment of coaptation.

Methods

A first prototype allowing three-dimensional mapping of coaptation forces was developed and a provisional patent was filed. A number of features informed the design of the new device, including force sensitivity, flexibility, and biocompatibility. Varying sensing technologies were screened (including piezo-electric, piezo-resistive, and resistive sensors), and a specific device to hold the sensor was designed and prototyped.

Results

The first generation of prototype was tested on a porcine ex vivo beating heart model. The device was inserted between the mitral leaflet through a left atrial incision between two running sutures. The sensor was positioned and connected to a custom-made acquisition system. The coaptation signal was recorded in normal valves and after creation of a posterior central prolapse. We were able to obtain precise surface mapping of mitral coaptation forces in this model. The coaptation signal was notably more intense in the normal valve compare to the prolapsed valve in otherwise similar hemodynamic conditions (Fig. 1).

Conclusions

A mapping of coaptation forces along the entire mitral valve surface can be achieved with the method and device we have developed. This technology may be useful to assist surgeons during MVr while providing real-time objective measurement in support of the conventional intraoperative morphological assessment. An extensive development roadmap has been developed and is being put in place to move our invention toward clinical trials.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2019  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 12 - N° 1

P. 179-180 - gennaio 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Mid-term valve stability after valve sparing aortic root replacement: Outcomes in bicuspid aortic valve compared with tricuspid aortic valve
  • N. D’ostrevy, A. Sawadogo, C. Lambert, E. Geoffroy, N. Dauphin, V. Eljezi, G. Clerfond, L. Camilleri
| Articolo seguente Articolo seguente
  • Surgical excision of atrial myxomas: 20 years experience of our department
  • A. Hfayedh, W. Ragmoun, M. Lajmi, M. Nasr Khouaja, M. Naouar, H. Lahdhili, S. Chenik

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.