Abstract

Purpose

To investigate the capabilities of multiparametric MRI including dynamic contrast enhanced (DCE) perfusion and diffusion-weighted imaging (DWI) to discriminate between benign and malignant ovarian masses.

Methods

A total of 43 women with a total of 43 ovarian masses were retrospectively included. They had a mean age of 51.26±18.05 (SD) years (range: 20–88years). Twenty women had benign and 23 had malignant ovarian tumors. All women had multiparametric MRI examinations including DWI (b50-b800) and DCE perfusion imaging at 1–5T. Results of DWI (apparent diffusion coefficient [ADC], b-800) and DCE imaging (volume transfer coefficient [Ktrans], rate constant [Kep], interstitial volume [Ve], initial area under the curve [iAUC]) were compared between benign and malignant ovarian masses.

Results

Mean ADC was significantly lowed in malignant tumors (0.92±0.25 [SD]×10−3 mm2/s (range: 0.6–1.6×10−3 mm2/s) than in benign tumors (1.37±0.69 [SD]×10−3 mm2/s; range: 0.4–2.9×10−3 mm2/s) (P=0.011). B-800 was significantly greater in malignant tumors (80.61±24.73 [SD] s/mm2; range: 24–110 s/mm2) than in benign ones (61.15±22.17 [SD] s/mm2; range: 38–155 s/mm2) (P=0.010). Ktrans was lower in benign tumors (0.13±0.06 [SD] min−1; range: 0–0.2min−1) than in malignant ones (0.25±0.16 [SD] min−1; range: 0.1–0.8min−1) (P=0.002). Kep was significantly greater in malignant tumors (0.55±0.19 [SD] min−1; range: 0.1–1.9min−1) than in benign ones (0.44±0.38 [SD] min−1; range: 0.2–1.1min−1) (P=0.003). iAUC was greater in malignant tumors (15.59±7.98 [SD] mM/min; range: 6.6–42.1mM/min) than in benign ones (7.98±5.06 [SD] mM/min; range: 0.2–17.7mM/min) (P=0.001). No differences in Ve were found between benign and malignant masses (P=0.084). The area under the ROC curve was significant for all parameters but Ve. Logistic regression analysis revealed 5.590 and 11.637 times higher malignancy risk for an ADC0.93×10−3 mm2/s and an iAUC13.88mM/min, respectively.

Conclusion

Multiparametric MRI has high accuracy in discrimination between benign and malignant ovarian masses. Therefore, adding these methods to the more common MRI protocol can help select the best treatment option in women with ovarian mass.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Multiparametric magnetic resonance imaging, Apparent diffusion coefficient (ADC), Dynamic contrast enhancement (DCE) perfusion, Logistic models, Ovarian neoplasms


Mappa


© 2020  Société française de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 3

P. 147-155 - marzo 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Assessment of ventricular tachyarrhythmia in patients with hypertrophic cardiomyopathy with machine learning-based texture analysis of late gadolinium enhancement cardiac MRI
  • D. Alis, A. Guler, M. Yergin, O. Asmakutlu
| Articolo seguente Articolo seguente
  • Positron emission tomography/computed tomography guided percutaneous biopsies of Ga-68 avid lesions using an automated robotic arm
  • R. Kumar, B.R. Mittal, A. Bhattacharya, S.K. Vadi, H. Singh, A. Bal, J. Shukla, H. Singh, V. Sharma, A. Sood, S.K. Singh

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.