Abbonarsi

Inter- and intra-observer reproducibility of ultrasound analysis of the long head of the biceps - 10/04/20

Doi : 10.1016/j.otsr.2019.11.025 
Matthieu Mazaleyrat a, b, , Raphaël Barthélémy c, Loïc Bouilleau b, d, Christophe Charousset e, Julien Berhouet a, b
a Service de Chirurgie Orthopédique et Traumatologique 1&2, CHRU de Tours, Avenue de la République, 37170 Chambray-les-Tours, France 
b Faculté de Médecine, Université de Tours, PRES Centre-Val de Loire Université, Tours, France 
c Service de Radiologie, Clinique d’Imagerie Médicale - Groupe du Mail, 19 Avenue Marie Reynoard, 38100 Grenoble, France 
d Service de Radiologie Adulte, CHRU de Tours, Avenue de la République, 37170 Chambray-les-Tours, France 
e IOAPC Institut Ostéo-Articulaire Paris Courcelles, Paris 8, 60 Rue de Courcelles, 75008 Paris, France 

Corresponding author. Service de Chirurgie Orthopédique et Traumatologique 1&2, CHRU de Tours, Avenue de la République, 37170 Chambray-les-Tours, France.Service de Chirurgie Orthopédique et Traumatologique 1&2, CHRU de ToursAvenue de la RépubliqueChambray-les-Tours37170France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Ultrasound assessment of the long head of the biceps (LHB) is difficult. The aim of the present study was to analyze the inter- and intra-observer reproducibility of 2 ultrasound cross-sections not previously assessed: humeral head apex (image 1) and bicipital groove entrance (image 2).

Hypothesis

These ultrasound cross-sectional images allow reliable and reproducible analysis of the intra-articular LHB.

Material and methods

A single-center prospective study was conducted. Inter-observer reproducibility was assessed between 2 radiologists in 20 healthy shoulders (asymptomatic group) and 35 painful shoulders (symptomatic group); intra-observer reproducibility was assessed for 1 observer in 10 healthy shoulders. Quantitative parameters comprised short and long axes and transverse area, and qualitative parameters comprise echogenicity and LHB position.

Results

On images 1 and 2, inter-observer agreement on the 3 quantitative parameters was good to excellent in both subject groups (p<0.05), and more precise and highly reproducible for image 1. Agreement on the 2 qualitative parameters was excellent (p<0.001). Intra-observer reproducibility results were non-significant on all parameters.

Discussion

The 2 intra-articular LHB cross-sections proved reliable and reproducible in painful and in healthy shoulders. A standardized ultrasound protocol could thus enhance the precision of LHB assessment and treatment. The difficulties of LHB measurement, often related to shoulder pathology, may, however, hinder interpretation.

Level of evidence

III, prospective intra- and inter-observer study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Shoulder, Long head of the biceps, Ultrasound, Diagnosis


Mappa


© 2020  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 106 - N° 2

P. 235-239 - aprile 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Contribution of postoperative ultrasound to early detection of anchor pullout after rotator cuff tendon repair: Report of 3 cases
  • Vincent Martinel, Nicolas Bonnevialle
| Articolo seguente Articolo seguente
  • Do short stems influence the cervico-diaphyseal angle and the medullary filling after reverse shoulder arthroplasties?
  • Alexandre Lädermann, Joe Chih-Hao Chiu, Grégory Cunningham, Anthony Hervé, Sébastien Piotton, Hugo Bothorel, Philippe Collin

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.