Prospective randomized study using EBRA-FCA to compare bone fixation between cementless SL-PLUS Zweymüller versus SL-PLUS MIA femoral implants in primary total hip arthroplasty with clinical assessment at a minimum 5 years’ follow-up - 25/04/20

Doi : 10.1016/j.otsr.2019.10.011 
Etienne Caron a, b, , Henri Migaud a, b, Gilles Pasquier a, b, Julien Girard a, b, Sophie Putman a, b
a Université Lille Nord de France, 59000 Lille, France 
b Service d’Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France 

Corresponding author at: Service d’Orthopédie, Hôpital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille cedex, France.Service d’Orthopédie, Hôpital Salengro, CHRU de LillePlace de VerdunLille cedex59037France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Sometimes the slightest changes in implant design can lead to failure, even for a validated prosthesis. A minimally invasive cementless model, the SL-PLUS MIA™, in which the lateral shoulder is eliminated, was developed from the Zweymüller SL-PLUS™ implant. After satisfactory in-vitro tests, it required in-vivo assessment to ensure that bone fixation is good. We therefore conducted a prospective randomized study comparing the two versions of the Zweymüller femoral stem, with the aim of (1) comparing bone fixation up to 2 years’ follow-up on EBRA-FCA radiography; and (2) assessing any difference in clinical or radiographic performance.

Hypothesis

Primary stability assessed on EBRA-FCA does not significantly differ between the SL-PLUS MIA™ and SL-PLUS™ implants.

Patients and method

A single-center multi-surgeon prospective randomized study included 80 patients (79 were operated on) between April 2009 and October 2012, with a mean 6 years’ follow-up. Radiographic assessment used the EBRA-FCA application up to 2 years’ follow-up; clinical assessment, with a minimum 5 years’ follow-up, was performed by a single observer, using the Harris and Oxford-12 scores. The two groups, SL-PLUS™ (n=38) and SL-PLUS MIA™ (n=41), were comparable in gender, age, indications, body-mass index and preoperative functional status.

Results

At a minimum 2 years’ follow-up, 24 SL-PLUS™ and 27 SL-PLUS MIA™ implants were analyzed on EBRA-FCA. Mean migration was respectively -0.3mm±0.8 [range, −1.6 to 1.3] and −0.5mm±0.7 [range, −2.2 to 0.5] (p=0.21). There was likewise no significant difference in varus tilt. The number of ectopic ossifications did not differ, despite the absence of shoulder: 7 with SL-PLUS™ (23%), and 10 with SL-PLUS MIA™ (32%), without clinical impact. Oxford score improved from 43±6.8 to 19±7 at 5 years’ follow-up with SL-PLUS ™ and from 44±8.8 to 20±7.4 with SL-PLUS MIA™: i.e., no significant inter-group difference. Likewise, Harris score at 2 years’ follow-up did not differ: 91.6±8.7 and 89.7±10.2, respectively. Implant survival did not differ: SL-PLUS MIA™, 41/41 (100%); SL-PLUS™, 36/38 (94.7%) (p=0.13).

Conclusion

There was no significant difference in fixation quality between the SL-PLUS™ and SL-PLUS MIA™ implants. Elimination of the shoulder did not jeopardize primary or secondary fixation, but neither did it reduce the rate of ossification. The modified Zweymüller implant appeared risk-free at 6 years’ follow-up.

Level of evidence

II, low-power prospective randomized study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip arthroplasty, Cementless stem, Primary stability, Stem migration, EBRA-FCA


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 106 - N° 3

P. 519-525 - maggio 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Can dual mobility cups prevent dislocation without increasing revision rates in primary total hip arthroplasty? A systematic review
  • Ragna C. Jonker, Loes W.A.H. van Beers, Bart C.H. van der Wal, H. Charles Vogely, Sebastien Parratte, René M. Castelein, Rudolf W. Poolman
| Articolo seguente Articolo seguente
  • Hip resurfacing generates a more physiological gait than total hip replacement: A case-control study
  • Cedric Maillot, Edouard Auvinet, Ciara Harman, Justin Cobb, Charles Rivière

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.