Abbonarsi

Recommandations du CIRTACI sur l’optimisation de l’injection des produits de contraste iodés en tomodensitométrie – Applications oncologiques - 08/06/20

Guidelines to use iodine contrast agent in vascular computed tomography examinations

Doi : 10.1016/j.jidi.2020.03.002 
A.L. Gaultier a , D. Mandry b , F. Pontana b , B. Morel c , E. Blondiaux c , G. Kuchcinski d , S. Kremer d , J. Grégory e , V. Laurent e , Jean-P. Tasu e , C. Balasa f , N. Grenier f , G. Bierry g , M. Lacroix h , S. Bommart h , P. Akl i , C. Colin i , F. Cornelis j , P. Coquel k , C. Fortel k , O. Clément l,
a CIREOL (Société Francophone d’Imagerie Tête et Cou), France 
b SFICV (Société Française d’Imagerie Cardiovasculaire), France 
c SFIPP (Société Francophone d’Imagerie Pédiatrique et Prénatale), France 
d SFNR (Société Française de Neuroradiologie), France 
e SIAD (Société d’Imagerie Abdominale et Digestive), France 
f SIGU (Société d’Imagerie Génito-Urinaire), France 
g SIMS (Société d’Imagerie Musculo-Squelettique), France 
h SIT (Société d’Imagerie Thoracique), France 
i SIFEM (Société d’Imagerie de la Femme), France 
j FRI (Fédération de Radiologie Interventionnelle), France 
k FNMR (Fédération Nationale des Médecins Radiologues), France 
l CIRTACI-SFR (Comité Interdisciplinaire de Recherche et de Travail sur les Agents de Contraste en Imagerie-Société Française de Radiologie), France 

Auteur correspondant : Radiologie, hôpital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris, France.Radiologie, hôpital europeen Georges-Pompidou20, rue LeblancParis75015France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Résumé

Introduction

Le CIRTACI propose dans cet article des recommandations pour optimiser la qualité des examens oncologiques en tomodensitométrie et la dose d’iode injectée.

Points importants

La recommandation propose une méthodologie de minimisation de la dose d’iode injectée en partant d’une dose de 0,5 gramme d’iode/kg à 120kV, ou 0,4 gI/kg à 100kV ou 0,3 gI/kg à 80kV. Chez les obèses, il faut calculer la dose en fonction de la surface corporelle plutôt qu’au poids.

Conclusion

L’utilisation des produits de contraste iodé doit répondre à des objectifs de qualité de prise en charge des patients. Ces recommandations répondent à cet impératif.

Il testo completo di questo articolo è disponibile in PDF.

Summary

Introduction

In this article, CIRTACI offers recommendations to optimize the quality of oncologic computed tomography examinations and the iodine dose.

Major points

The paper describes a method to minimize the injected iodine dose, starting with a dose of 0.4 gI/kg at 100kV ou 0.3 gI/kg at 80kV. In obese patients, the paper proposes to calculate the dose based on body surface rather than weight.

Conclusion

These recommendations provide useful points to help radiologists concerning the use of iodine contrast agent.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Produits de contraste iodé, TDM, Oncologie

Keywords : Iodine, Guidelines, CT, Oncology


Mappa


© 2020  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 3 - N° 3

P. 145-150 - giugno 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Editorial board
| Articolo seguente Articolo seguente
  • Recommandations du CIRTACI sur l’optimisation de l’injection des produits de contraste iodé en tomodensitométrie – Explorations vasculaires
  • A.L. Gaultier, D. Mandry, F. Pontana, B. Morel, E. Blondiaux, G. Kuchcinski, S. Kremer, J. Grégory, V. Laurent, Jean-P. Tasu, C. Balasa, N. Grenier, G. Bierry, M. Lacroix, S. Bommart, P. Akl, C. Colin, F. Cornelis, P. Coquel, C. Fortel, O. Clément

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.