Abbonarsi

Accuracy of artificial intelligence–assisted detection of upper GI lesions: a systematic review and meta-analysis - 21/09/20

Doi : 10.1016/j.gie.2020.06.034 
Thomas K.L. Lui, MBBS, MMedSc, MRCP, Vivien W.M. Tsui, MBBS, MRCP, Wai K. Leung, MD, FRCP ⁎
 Department of Medicine, Queen Mary Hospital, University of Hong Kong, Hong Kong 

∗Reprint requests: Wai K. Leung, Department of Medicine, Queen Mary Hospital, University of Hong Kong, 102 Pokfulam Rd, Hong Kong.Department of MedicineQueen Mary HospitalUniversity of Hong Kong102 Pokfulam RdHong Kong

Abstract

Background and Aims

Artificial intelligence (AI)-assisted detection is increasingly used in upper endoscopy. We performed a meta-analysis to determine the diagnostic accuracy of AI on detection of gastric and esophageal neoplastic lesions and Helicobacter pylori (HP) status.

Methods

We searched Embase, PubMed, Medline, Web of Science, and Cochrane databases for studies on AI detection of gastric or esophageal neoplastic lesions and HP status. After assessing study quality using the Quality Assessment of Diagnostic Accuracy Studies tool, a bivariate meta-analysis following a random-effects model was used to summarize the data and plot hierarchical summary receiver-operating characteristic curves. The diagnostic accuracy was determined by the area under the hierarchical summary receiver-operating characteristic curve (AUC).

Results

Twenty-three studies including 969,318 images were included. The AUC of AI detection of neoplastic lesions in the stomach, Barrett’s esophagus, and squamous esophagus and HP status were .96 (95% confidence interval [CI], .94-.99), .96 (95% CI, .93-.99), .88 (95% CI, .82-.96), and .92 (95% CI, .88-.97), respectively. AI using narrow-band imaging was superior to white-light imaging on detection of neoplastic lesions in squamous esophagus (.92 vs .83, P < .001). The performance of AI was superior to endoscopists in the detection of neoplastic lesions in the stomach (AUC, .98 vs .87; P < .001), Barrett’s esophagus (AUC, .96 vs .82; P < .001), and HP status (AUC, .90 vs .82; P < .001).

Conclusions

AI is accurate in the detection of upper GI neoplastic lesions and HP infection status. However, most studies were based on retrospective reviews of selected images, which requires further validation in prospective trials.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : AI, AUC, CI, CNN, HP, NBI, SVM, WLI


Mappa


 DISCLOSURE: The following author disclosed financial relationships: W. K. Leung: Consultant for Medtronics. All other authors disclosed no financial relationships.
 If you would like to chat with an author of this article, you may contact Dr Leung at waikleung@hku.hk.


© 2020  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 92 - N° 4

P. 821 - ottobre 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • A primer on artificial intelligence and its application to endoscopy
  • Daljeet Chahal, Michael F. Byrne
| Articolo seguente Articolo seguente
  • Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis
  • Shelly Soffer, Eyal Klang, Orit Shimon, Noy Nachmias, Rami Eliakim, Shomron Ben-Horin, Uri Kopylov, Yiftach Barash

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.