Optimising micro computed tomography imaging of large animal and human hearts at high resolution - 25/09/20

Doi : 10.1016/j.acvdsp.2020.03.163 
N. Pallares Lupon 1, 2, , J. Duchâteau 1, 3, L. Yessad 1, 2, M. Constantin 1, 2, G. Ramlugun 1, 2, D. Gerneke 4, G. Sands 4, M.L. Trew 4, B. Smaill 4, M. Hocini 1, 3, M. Haissaguerre 1, 3, E. Vigmond 5, 6, B. Quesson 1, 2, O. Bernus 1, 2, R. Walton 1, 2
1 IHU Liryc - L’Institut de RYthmologie et Modélisation Cardiaque - Fondation Bordeaux Université 
2 CRCTB - Centre de Recherche Cardio-Thoracique de Bordeaux - Inserm, U1045 - Université de Bordeaux 
3 CHU Bordeaux, Bordeaux, France 
4 Auckland Bioengineering Institute, University of Auckland, Auckland, Nouvelle-Zélande 
5 Department of Electrical and Computer Engineering, University of Calgary, Calgary, Canada 
6 IMB - Institut de mathématiques de Bordeaux, Bordeaux, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Riassunto

Introduction

Micro Computed tomography has emerged as a powerful imaging tool to study the micro-structure of cardiac tissue of small mammals. However, conventional techniques in whole organs of large mammals, is compromised due to the use of high molecular weight contrast agents and the relative thickness of samples.

Objective

To develop a tissue preparation method to optimize microCT imaging of whole hearts with sizes including those of humans.

Methods

Male pig hearts (N=5) were treated by: hydrated samples with conventional contrast agent (iodine, 0.5%) or dehydrated in ethanol and air-dried under hexamethyldisilazane (HMDS). Human hearts (N=3) were treated using air-drying method. Hearts were imaged at 21.7μm isotropic resolution by microCT (SkyScan 1276 Bruker). Images were quantified with Amira software using a 3D cylinder correlation technique.

Results

The X-ray attenuation of air-dried samples was better optimized for the bandwidth of the X-ray detector, indicated by reduced x-ray attenuation (pig 65%, human 55), compared to almost complete signal attenuation from hydrated samples (93%). Voxel intensity histograms showed two populations corresponding to the tissue and the background media and sample support structures. Yet, the separating minima of histogram intensities were always observed at lower intensities for air-dried hearts (Figure 1A) than hydrated hearts, increasing the dynamic range for tissue-specific signals (Figure 1B). Imaging air-dried pig or human hearts permitted a simple threshold-based segmentation to isolate microstructures of the heart, including vessels, myocardial fibers and Purkinje from the background (1C). Fiber orientation quantification could be performed directly on unfiltered images. Fiber orientation was validated against subsequent histology of the same samples.

Conclusion

Air drying with HMDS enables microCT imaging of human-sized hearts while preserving micro-structure and the identification of individual cardiac muscle fibers.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2020  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 12 - N° 2-4

P. 268-269 - ottobre 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Acute hexosamine pathway activation induces cardiac arrhythmia
  • M. Douard, F. Vaillant, E. Abell, E. White, P. Dos Santos, F. Brette

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.