Abbonarsi

Learning Curve and Initial Experience With Implementation of a His-Bundle Pacing Program in an Australian Setting - 08/10/20

Doi : 10.1016/j.hlc.2020.01.003 
Luke P. Dawson, MBBS, MPH a, Julie Cadden, MBBS a, Derk Pol, MBBS a, Gareth Wynn, MBChB, MD(Res) a, Leeanne Grigg, MBBS a, Jonathan Kalman, MBBS, PhD a, b, Irene Stevenson, MBBS a,
a Department of Cardiovascular Medicine, Royal Melbourne Hospital, Melbourne, Vic, Australia 
b Department of Medicine, University of Melbourne, Melbourne, Vic, Australia 

Corresponding author at: Department of Cardiology, The Royal Melbourne Hospital, 300 Grattan St, Parkville, Victoria 3050, Australia; Tel.: 03 9342 7000Department of CardiologyThe Royal Melbourne Hospital300 Grattan StParkvilleVictoria3050Australia.

Abstract

Background

His-bundle pacing (HBP) has emerged as a promising technique to avoid pacing complications associated with dyssynchrony from right ventricular pacing, but data are limited to experienced operators and centres. We aimed to evaluate the implementation and outcomes of an HBP program in an Australian setting.

Methods

Data were retrospectively collected on 140 consecutive HBP procedures attempted at three centres from March 2018 to September 2019. The cohort was divided into three groups (early: procedures 1–47, middle: 48–94, late: 95–140) to determine changes in procedural success in relation to operator experience.

Results

Median age was 76 years (IQR 68–80 yrs); 69% were male. Atrial fibrillation was present in 59%, left ventricular ejection fraction (LVEF) ≤40% in 25%, and left and right bundle branch blocks present in 23% and 16% respectively, and atrioventricular (AV) block was present in 26%. Overall procedural success was 87%, median implant threshold 0.8V@1 ms, and QRS duration improved in 64% of procedures. Procedural success (early 83%, middle 89%, late 89%, p=0.58) was not different, while median procedural time (early 98 mins, middle 83 mins, late 70 mins, p<0.001) improved across operator experience groups. Lower success rates were identified for patients with AV block (73% vs. 92%, p<0.01), a previous device (69% vs. 89%, p=0.02), moderate-severe TR (69% vs. 88%, p=0.04), and when right-sided access was required (25% vs. 89%, p<0.01).

Conclusions

His-bundle pacing is a feasible procedure with continued improvement in procedural measures of success after an early learning period. The presence of AV block, a previous device, significant tricuspid regurgitation, or right-sided access may affect procedural success.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : HIS-bundle pacing, Cardiac resynchronisation, Operator experience


Mappa


© 2020  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 29 - N° 10

P. 1493-1501 - ottobre 2020 Ritorno al numero
Articolo precedente Articolo precedente
  • Atrial Flutter and Fibrillation Following Lung Transplantation: Incidence, Associations and a Suggested Therapeutic Algorithm
  • Hayley Barnes, Greta Gurry, David McGiffin, Glen Westall, Kovi Levin, Miranda Paraskeva, Helen Whitford, Trevor Williams, Greg Snell
| Articolo seguente Articolo seguente
  • Is Peripheral Artery Disease an Independent Predictor of Isolated Coronary Artery Bypass Outcome?
  • Massimo Bonacchi, Orlando Parise, Francesco Matteucci, Cecilia Tetta, Amalia Ioanna Moula, Linda Renata Micali, Aleksander Dokollari, Marco De Martino, Guido Sani, Andrea Grasso, Edvin Prifti, Sandro Gelsomino

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.