Abbonarsi

Synchronized Inflations Generate Greater Gravity-Dependent Lung Ventilation in Neonates - 17/12/20

Doi : 10.1016/j.jpeds.2020.08.043 
Georgie Dowse, BSci (Hon) 1, 2, Elizabeth Perkins, RN 1, 3, Jessica Thomson, BSci (Hon) 1, 2, Nicholas Schinckel, BSci (Hon) 1, 2, Prue Pereira-Fantini, BSci (Hon) PhD 1, 2, David Tingay, MBBS, DCH, FRACP, PhD 1, 2, 3,
1 Neonatal Research, Murdoch Children's Research Institute, Parkville, Australia 
2 Department of Paediatrics, The University of Melbourne, Parkville, Australia 
3 Department of Neonatology, The Royal Children's Hospital, Parkville, Australia 

Reprint requests: David Tingay, MBBS, DCH, FRACP, PhD, Neonatologist, Royal Children's Hospital, Department of Neonatology, 50 Flemington Rd, Parkville, 3053 AustraliaRoyal Children's HospitalDepartment of Neonatology50 Flemington RdParkville3053Australia

Abstract

Objective

To describe the regional distribution patterns of tidal ventilation within the lung during mechanical ventilation that is synchronous or asynchronous with an infant's own breathing effort.

Study design

Intubated infants receiving synchronized mechanical ventilation at The Royal Children's Hospital neonatal intensive care unit were studied. During four 10-minute periods of routine care, regional distribution of tidal volume (VT; electrical impedance tomography), delivered pressure, and airway flow (Florian Respiratory Monitor) were measured for every inflation. Post hoc, each inflation was then classified as synchronous or asynchronous from video data of the ventilator screen, and the distribution of absolute VT and delivered ventilation characteristics determined.

Results

In total, 2749 inflations (2462 synchronous) were analyzed in 19 infants; mean (SD) age 28 (30) days, gestational age 35 (5) weeks. Synchronous inflations were associated with a shorter respiratory cycle (P = .004) and more homogenous VT (center of ventilation) along the right (0%) to left (100%) lung plane; 45.3 (8.6)% vs 48.8 (9.4)% (uniform ventilation 46%). The gravity-dependent center of ventilation was a mean (95% CI) 2.1 (−0.5, 4.6)% toward the dependent lung during synchronous inflations. Tidal ventilation relative to anatomical lung size was more homogenous during synchronized inflations in the dependent lung.

Conclusions

Synchronous mechanical ventilator lung inflations generate more gravity-dependent lung ventilation and more uniform right-to-left ventilation than asynchronous inflations.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : synchronization, infant, regional ventilation, mechanical ventilation

Abbreviations : CoVRL, CoVVD, EIT, NICU, PEEP, PIP, ROI, SpO2, VT, VTao, VTEIT


Mappa


 Supported by the Victorian Government Operational Infrastructure Support Program (Melbourne, Australia). G.D. and N.S. received an MCRI Honours student scholarship. D.T. is supported by a National Health and Medical Research Council Clinical Career Development Fellowship (1053889). SenTec AG (Landquart, Switzerland) manufactured custom-built EIT belts for infants. All EIT hardware was purchased by Murdoch Children's Research Institute (MCRI) without any restrictions. The authors declare no conflicts of interest.


Crown Copyright © 2020  Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 228

P. 24 - gennaio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • 50 Years Ago in The Journal of Pediatrics : Hypocomplementemic Glomerulonephritis
  • Sharon P. Andreoli
| Articolo seguente Articolo seguente
  • Clinical Factors Influencing Time to Decannulation in Children with Tracheostomy and Ventilator Dependence Secondary to Bronchopulmonary Dysplasia
  • Julie Fierro, Joseph Piccione, Scott Lorch

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.