Abbonarsi

Correlation between ejection dynamic parameters and usual echocardiographic methods for assessing aortic stenosis: A prospective study - 09/01/21

Doi : 10.1016/j.acvdsp.2020.10.073 
S. Serbout , A. Eladaoui, A. Ech-Chenbouli, S. Arous, L. Azzouzi, R. Habbal
 Cardiologie, CHU Ibn-Rochd, Casablanca, Morocco 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Riassunto

Introduction

Aortic stenosis (AS) was the most frequent valve disease referred for surgical treatment in developed countries. The management of the disease depends of AS severity. Echocardiography is the mainstay of assessment, and three parameters are recommended for AS severity evaluation: effective orifice area, mean aortic gradient, and peak jet velocity.

Objective

Our study was to evaluate acceleration time (AT) and the ratio the AT/ET (ejection time) ratio as diagnostic parameters in AS and to analyse the defining characteristics of the aortic waveform.

Material and methods

Patients with AS were prospectively enrolled. Quantitative echocardiographic Doppler parameters including ejection dynamics (AT, ET, and AT/ET ratio) as well as conventional and clinical parameters were analysed. AT, ET, and AT/ET ratio were calculated in different stages of AS.

Results

Fifty-one patients were included (mean age, 56 years; 54% women), of whom 37 (74%) had severe AS and 14 (26%) patients had moderate AS; AT was higher in patients with higher levels of severity (121 vs. 85 msec, P<0.001), as well as AT/ET ratios (28% vs. 37%, P<0.001) (Table 1). Using a cut-off of 80 msec for AT and 32% for AT/TE, while there were no differences in ET (297 vs. 300ms, P=0.66). Receiver operating characteristic analysis showed that AT and AT/ET ratio could discriminate severe AS, whereas ET could not. We found good correlations between both ejection parameters (AT and AT/ET ratio) and all the usual echocardiographic methods for assessing AS (Fig. 1).

Conclusion

The present study shows that systolic time intervals, particularly AT and AT/ET ratio, are easy and accurate methods that are related to AS severity and could be used as alternatives in the echocardiographic assessment of this disease.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2020  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 13 - N° 1

P. 65-66 - gennaio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Poster: Cardiovascular magnetic resonance analysis for discrimination between hypertensive heart disease and hypertrophic cardiomyopathy
  • T. Filali, F. Walylo
| Articolo seguente Articolo seguente
  • Echocardiography in COVID-19 patients and its impact on treatment change
  • N. Benyounes, C. Van Der Vynckt, T. Tibi

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.