Abstract

Background

Precise implant alignment is a crucial prognostic factor for successful outcomes following total hip arthroplasty (THA). A portable accelerometer-based navigation (PN) device may achieve the same accuracy as that achieved by the computer-assisted navigation surgery technique, with the convenience of a conventional technique. Although the usefulness of PN in THA (PN-THA) has been reported, whether it is more accurate than performing THA with a conventional technique (CON-THA) remains controversial. The difference in surgical time between PN-THA and CON-THA is also unclear. Therefore, we conducted a systematic review and meta-analysis of studies comparing results of PN-THA with those of CON-THA. We focused on the following question: is PN-THA superior to CON-THA in terms of radiological parameters and surgical time?

Patients and Methods

A literature search was conducted in PubMed, Web of Science, and Cochrane Library, to identify studies that met the following inclusion criteria: randomised controlled trials (RCT) or non-RCT, studies involving patients who underwent PN-THA and patients who underwent CON-THA, studies including data on radiological parameters and surgical outcomes. Author names, publication year, country, study design, surgical approach, demographic characteristics of the participants (diagnosis, gender, age, and body mass index), and surgical outcomes (the radiological parameters and the surgical time) were extracted. We calculated the mean differences (MDs) for continuous data with 95% confidence intervals (CIs) for each outcome. p<0.05 was considered significant.

Results

Three studies were included in this meta-analysis. The meta-analysis showed that absolute deviation of the postoperative measured angles from the target position for the cup anteversion was significantly smaller in PN-THA than in CON-THA (MD=−1.70, 95% CI=−2.91 to −0.50, [p=0.005]). There was no significant difference in the absolute deviation of the postoperative measured angles from the target position for cup abduction between the groups (MD=−1.82, 95% CI=−4.32–0.67, [p=0.15]). The surgical time was significantly longer in PN-THA than in CON-THA (MD=8.58, 95% CI=4.05–13.10, [p=0.0002]).

Discussion

This systematic review and meta-analysis of studies comparing the results of PN-THA with those of CON-THA showed that the PN-THA is advantageous for precise cup implantation compared to CON-THA, although PN-THA has a longer surgical time compared to CON-THA.

Level of evidence

III.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip arthroplasty, Portable, Hand-held, Navigation, Systematic review, Meta-analysis

Abbreviations : PN, CON, MD, RCT, CAS


Mappa


© 2020  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 1

Articolo 102742- febbraio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Cementless hip revision cup for the primary fixation of osteoporotic acetabular fractures in geriatric patients
  • Christopher A. Becker, Christoph Linhart, Jan Bruder, Christian Zeckey, Axel Greiner, Adrian Cavalcanti Kußmaul, Simon Weidert, Eduardo M. Suero, Wolfgang Böcker, Christian Kammerlander
| Articolo seguente Articolo seguente
  • Symptomatic leg length discrepancy after total hip arthroplasty is associated with new onset of lower back pain
  • Felix W.A. Waibel, Kersten Berndt, Thorsten Jentzsch, Jan Farei-Campagna, Stefan Rahm, Claudio Dora, Patrick O. Zingg

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.