Abbonarsi

Robot-assisted versus stereotactic frame-based stereoelectroencephalography in medically refractory epilepsy - 14/03/21

Doi : 10.1016/j.neucli.2020.11.001 
Jie Zheng a, 1, Ying-Li Liu b, c, 1, Di Zhang a, Xue-Hua Cui a, Lin-Xia Sang a, Tao Xie d, Wen-Ling Li a,
a Department of Neurosurgery, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang 050000, China 
b Department of Epidemiology and Statistics, School of Public Health, Hebei Medical University, 361 East Zhongshan Road, Shijiazhuang 050017, China 
c Hebei Province Key Laboratory of Environment and Human Health, 361 East Zhongshan Road, Shijiazhuang 050017, China 
d Department of Neurology, The Second Hospital of Hebei Medical University, 215 West Heping Road, Shijiazhuang 050000, China 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 9
Iconografia 2
Video 0
Altro 0

Abstract

Aim

To explore the difference between robot assisted (RA) and stereotactic frame based (SF) stereoelectroencephalography (SEEG) in patients with medically refractory epilepsy.

Methods

We undertook a retrospective review of 33 SEEG cases at our center, of which 14 were SF performed from March to October 2018 and 19 were RA performed from November 2018 to December 2019. Detailed review of medical histories and operative records as well as imaging and trajectory plans was carried out for each patient, and the results related to each technique compared. A multiple linear regression model was used to test for variables that significantly influenced placement error.

Results

Compared to the SF group, the RA group had a higher mean number of electrodes per patient (10.7 ± 2.8 versus 6.4 ± 0.8, P < 0.0001) and a significantly shorter mean operative time (127.3 ± 40.7 versus 152.7 ± 13.6 min, P = 0.033). For the RA group, the intracranial implantation length was positively correlated with target point error (p = 0.000), depth error (p = 0.043), and two-dimensional (2D) radial error (p = 0.041). Conversely, skull thickness was negatively correlated with the TP error (p = 0.004), depth error (p = 0.037) and 2D radial error (p = 0.000). We also analyzed the mean entry point, target point, depth and 2D radial errors, the complication rates, and the results of epileptogenic zone (EZ) localization and Engel class. The results showed no difference in these aspects between the SF group and the RA group.

Conclusion

This study suggests that, compared to stereotactic frame based SEEG, robot assisted SEEG is significantly more efficient and comparable in safety and effectiveness.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : stereoelectroencephalography, epilepsy surgery, robot, in vivo application accuracy, epilepsy


Mappa


© 2020  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 51 - N° 2

P. 111-119 - marzo 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Continuous EEG monitoring in the follow-up of convulsive status epilepticus patients: A proposal and preliminary validation of an EEG-based seizure build-up score (EaSiBUSSEs)
  • Aurélie Hanin, Sophie Demeret, Vi-Huong Nguyen-Michel, Virginie Lambrecq, Vincent Navarro
| Articolo seguente Articolo seguente
  • Quantitative approach to early neonatal EEG visual analysis in hypoxic-ischemic encephalopathy severity: Bridging the gap between eyes and machine
  • Laure Lacan, Nacim Betrouni, Marie-Dominique Lamblin, Laurence Chaton, Arnaud Delval, Jean-Louis Bourriez, Laurent Storme, Philippe Derambure, Sylvie NguyenThe Tich

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.