Abbonarsi

Percutaneous Left Ventricular Assist Device Leads to Heart Rhythm Stabilisation in Cardiogenic Shock: Results from the Dresden Impella Registry - 16/03/21

Doi : 10.1016/j.hlc.2020.08.005 
Johannes Mierke, MD a, , Tobias Loehn, MD b, Georg Ende, MD a, Sabrina Jahn, MD a, Silvio Quick, MD c, Uwe Speiser, MD a, Stefanie Jellinghaus, MD a, Christian Pfluecke, MD a, Axel Linke, MD a, Karim Ibrahim, MD c
a Technische Universität Dresden, Department of Internal Medicine and Cardiology, Herzzentrum Dresden, University Clinic, Dresden, Germany 
b Kreiskrankenhaus Freiberg, Klinik für Innere Medizin II, Freiberg, Germany 
c Klinikum Chemnitz, Klinik für Innere Medizin I, Chemnitz, Germany 

Corresponding author at: Technische Universität Dresden, Department of Internal Medicine and Cardiology, Herzzentrum Dresden, University Clinic, Fetscherstraße 76, 01307 Dresden, Germany. Tel.: +49-351/450-1704; fax: +49-351/450-1702Technische Universität DresdenDepartment of Internal Medicine and CardiologyHerzzentrum DresdenUniversity ClinicFetscherstraße 76Dresden01307Germany

Abstract

Background

Severe heart rhythm disturbances (SHRDs) occur regularly in cardiogenic shock (CS). Percutaneous left ventricular assist devices (pLVADs) can actively unload the left ventricle (LV), decreasing left ventricular end-diastolic pressure and wall tension, which are suspected parameters for the induction and maintenance of arrhythmias. The aim of this study was to describe effects of LV unloading on SHRD.

Method

In the Dresden Impella Registry, 97 patients received an Impella CP in refractory CS. Of them, 19 had SHRDs, which were not stopped by common therapeutic strategies such as electrical defibrillation or antiarrhythmic drugs. They were only stopped after implantation of a micro-axial heart pump. This phenomenon was referred to as heart rhythm stabilisation (HRS). Clinical outcome and laboratory parameters were assessed and risk factors for the occurrence of HRS were identified.

Results

All 19 patients with refractory SHRD terminated immediately into a stable heart rhythm after insertion of the micro-axial heart pump. In 37% no additional defibrillation was needed. Of the patients with HRS, CS was mostly caused by myocardial infarction (68%). Resuscitation before pLVAD was performed in 89% for more than 30 minutes. Patients with HRS were resuscitated more frequently and for a longer duration than patients without HRS. After HRS, the serum lactate and norepinephrine dosage decreased in the first 12 hours, whereas left ventricular ejection fraction increased by 95%.

Conclusions

Left ventricular unloading in patients with CS seems to be an option for treating patients with sustained life-threatening tachycardia, who are refractory to common treatment.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cardiogenic shock, Electrical storm, Impella, Percutaneous left ventricular assist devices, Ventricular arrhythmia


Mappa


© 2020  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 30 - N° 4

P. 577-584 - aprile 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • A Stepwise Approach to Left Ventricular Assist Device Pump Thrombosis
  • Sinan Sabit Kocabeyoglu, Umit Kervan, Dogan Emre Sert, Mehmet Karahan, Ertekin Utku Unal, Zeki Catav, Mustafa Pac
| Articolo seguente Articolo seguente
  • Berlin Heart EXCOR Paediatric Ventricular Assist Device: Does Weight Matter?
  • Virginie Fouilloux, Fedoua El Louali, Célia Gran, Roland Henaine, François Roubertie, Caroline Chenu, Marion Fiorini, Stéphane Le Bel, Philippe Mauriat, Jean Neidecker, Loïc Macé, Bernard Kreitmann, Caroline Ovaert

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.