Introduction

Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long-term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers.

Objective

We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique.

Methods

We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators’ discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3- and 12-month follow-up.

Results

HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0±28.8min, and 7.3±8.1min (3.1±4.1Gy·cm2), respectively. The mean HB paced QRS duration was 106±18ms. The mean HB capture threshold was 1.29±0.77V and did not increase at 3- and 12-month follow-up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures (Fig. 1).

Conclusion

HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2021  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 13 - N° 2

P. 233-234 - maggio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Induced pluripotent cardiomyocytes from female CPVT patient present different Ca2+ mishandling than men
  • A. Val-Blasco, L. Yin, P. Gerbaud, R. Perrier, J.P. Benitah, A. Gomez
| Articolo seguente Articolo seguente
  • Correlation between CHA2DS2-VASc score and left atrium size in non-valvular atrial fibrillation
  • S. Antit, H. Chelbi, O. Zidi, M. Abdelhedi, E. Boussabeh, M. Thameur, L. Zakhama, S. Ben Youssef

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.