Abbonarsi

The standardized method and clinical experience may improve the reliability of visually assessed capillary refill time - 28/05/21

Doi : 10.1016/j.ajem.2020.04.007 
Koichiro Shinozaki, MD, PhD a, b, , Lee S. Jacobson, MD, PhD b, Kota Saeki c, Naoki Kobayashi, PhD d, Steve Weisner c, Julianne M. Falotico, BA b, Timmy Li, PhD b, Junhwan Kim, PhD a, Joshua W. Lampe, PhD a, e, Lance B. Becker, MD, FAHA a, b
a The Feinstein Institutes for Medical Research, Northwell Health System, Manhasset, NY, USA 
b Department of Emergency Medicine, North Shore University Hospital, Northwell Health System, Manhasset, NY, USA 
c Nihon Kohden Innovation Center, Cambridge, MA, USA 
d Nihon Kohden Corporation, Tokyo, Japan 
e ZOLL Medical, Chelmsford, MA, USA 

Corresponding author at: The Feinstein Institutes for Medical Research, Northwell Health System, 350 Community Dr., Manhasset, NY 11030, USA.The Feinstein Institutes for Medical ResearchNorthwell Health System350 Community Dr.,ManhassetNY11030USA

Abstract

Objective

Reliability of capillary refill time (CRT) has been questionable. The purpose of this study was to examine that a standardized method and clinical experience would improve the reliability of CRT.

Methods

This was a cross-sectional study in the emergency department (ED). Health care providers (HCPs) performed CRT without instruments (method 1) to classify patients as having normal or abnormal (≤2/>2 s) CRT. An ED attending physician quantitatively measured CRT using a chronograph (standardized visual CRT, method 2). A video camera was mounted on top of the hand tool to obtain a digital recording. The videos were used to calculate CRT via image software (image CRT, method 3) as a criterion standard of methods. Additionally, 9 HCPs reviewed the videos in a separate setting in order to visually assess CRT (video CRT, method 4).

Results

We enrolled 30 patients in this study. Standardized visual CRT (method 2) identified 10 abnormal patients, while two patients were identified by CRT without instruments (method 1). There was no correlation (κ value, 0.00) between CRT without instruments (method 1) and image CRT (method 3), however the correlation between standardized visual CRT (method 2) and image CRT (method 3) was strong (r = 0.64, p < 0.01). Both intra-observer reliability and correlation coefficient with image CRT (method 3) was higher in video CRT (method 4) by more experienced clinicians.

Conclusions

Visual assessment is variable but a standardized method such as using a chronograph and/or clinical experience may aid clinicians to improve the reliability of visually assessed CRT.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Capillary refill time, Visual assessment, Image analysis, Peripheral blood perfusion, Reliability


Mappa


© 2020  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 44

P. 284-290 - giugno 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Serum total carbon dioxide as a prognostic factor for 28-day mortality in patients with sepsis
  • Jin Hee Kim, Dong-Hyun Jang, You Hwan Jo, Gil Joon Suh, Woon Yong Kwon, Jae Hyuk Lee, Jonghwan Shin, Inwon Park, Che Uk Lee, Sang-Min Lee
| Articolo seguente Articolo seguente
  • Time to antibiotic administration: Sepsis alerts called in emergency department versus in the field via emergency medical services
  • Mark Mixon, Scott Dietrich, Michael Floren, Ryan Rogoszewski, Lindsay Kane, Nikiah Nudell, Lindsey Spears

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.