Abstract

Introduction: Detection of a pulse is crucial to decision-making in the care of patients who are in cardiac arrest, however, the current standard of manual pulse palpation is unreliable. An emerging alternative is the use of point-of-care ultrasound (POCUS) for direct assessment of the carotid pulse. The primary objective of this study is to determine the interobserver reliability for physician interpretation of pre-recorded point-of-care ultrasound pulse-check clips for patients who are in cardiac arrest. Methods: We conducted a web-based survey of residents and physicians working in an academic center. Participants were shown a tutorial demonstrating POCUS detection of the carotid pulse and then asked to interpret 15 carotid pulse ultrasound clips from patients who were in cardiac arrest. The primary outcome was interobserver reliability for carotid pulse assessment. Secondary outcomes included interobserver reliability stratified by physician role and POCUS experience, median tutorial and median pulse assessment duration. Interobserver reliability was determined by Krippendorff's ⍺. Results: 68 participants completed the study, with a response rate of 75%. There was high interobserver reliability for pulse assessment amongst all study participants (⍺ = 0.874, 95% CI 0.869 to 0.879). All sub-groups had ⍺ greater than 0.8. Median tutorial duration was 35 s (IQR 29). Median pulse assessment duration was 6 s (IQR 5) with 76% of assessments completed within 10 s. Conclusion: Interpretation of the carotid pulse by POCUS showed high interobserver reliability. Further work must be done to determine the performance of POCUS pulse assessment in real-time for patients who are in cardiac arrest.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Point-of-care ultrasound, Pulse check, Cardiac arrest


Mappa


© 2020  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 45

P. 280-283 - luglio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Tranexamic acid for gastrointestinal bleeding: A systematic review with meta-analysis of randomized clinical trials
  • Po-Lin Lee, Kai-Suan Yang, Hong-Wei Tsai, Sen-Kuang Hou, Yi-No Kang, Chun-Chao Chang
| Articolo seguente Articolo seguente
  • Efficacy of methylene blue in a murine model of amlodipine overdose
  • Lisandra E. de Castro Brás, Cecile L. Baccanale, Lex Eccleston, Trey Sloan, Jason C. St Antoine, Steven Matthew-Lewis Verzwyvelt, Peggy Pittman, Dorcas O'Rourke, William J. Meggs

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.