Abbonarsi

Low flow intermittent bronchoscopic oxygen insufflation to identify occult tracheo-esophageal fistulas - 21/09/21

Doi : 10.1016/j.rmed.2021.106544 
Hagit Levine a, b, , Tommy Schonfeld a, b, Shahar Handelsman a, Ophir Bar-On a, b, Guy Steuer a, b, Meir Mei-Zahav a, b, Dario Prais a, b, Patrick Stafler a, b
a Pulmonary Institute, Schneider Children's Medical Center, Petach Tikva, Israel 
b Sackler Faculty of Medicine, Tel Aviv University, Ramat Aviv, Israel 

Corresponding author. Pediatric Pulmonary Institute, Schneider Children's Medical Center of Israel Petach Tikva 49202, Israel.Pediatric Pulmonary InstituteSchneider Children's Medical Center of IsraelPetach Tikva49202Israel

Abstract

Background

Esophageal atresia and tracheo-esophageal fistula (TEF), a well described congenital anomaly of the aero-digestive tract, commonly presents with inability to swallow and feed immediately after birth. However, diagnosis of recurrent or isolated TEF can be challenging and requires a combination of endoscopic and contrast studies. We describe a hitherto unreported technique of low flow intermittent oxygen insufflation into the suspicious tract and examine its safety and diagnostic yield for identification of occult TEF.

Methods

A retrospective single center cohort study, analyzing case notes of patients with TEF who underwent bronchoscopic oxygen insufflation for suspected recurrent or isolated TEF between 2006 and 2019 at a tertiary pediatric hospital.

Results

One-hundred and seven patients with TEF underwent 142 bronchoscopies during the study period. Of these, 22 patients underwent 28 bronchoscopies with oxygen insufflation. Twelve (43%) open fistulas were identified; of these, 9 (75%) were found using oxygen insufflation, revealing the fistula in 4/9 (44%) cases that had not been apparent using simple bronchoscopic visualization alone. One fistula was missed with multiple investigations, including bronchography and found only using oxygen insufflation. No complications were encountered.

Conclusions

Recurrent or isolated TEF may be missed using ordinary flexible bronchoscopy and imaging studies. Low flow oxygen insufflation can be applied safely and may detect otherwise occult TEF.

Il testo completo di questo articolo è disponibile in PDF.

Highlights

Diagnosis of recurrent or isolated TEF can be challenging.
Recurrent or isolated TEF may be missed using ordinary flexible bronchoscopy and imaging studies.
Low flow oxygen insufflation bursts technique can be applied safely and may detect occult TEF.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Tracheoesophageal fistula, Bronchoscopy


Mappa


© 2021  Elsevier Ltd. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 186

Articolo 106544- settembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Rapid access rehabilitation after exacerbations of COPD – A qualitative study
  • Ana Oliveira, Shirley Quach, Sanaa Alsubheen, Sabrina Dasouki, Jan Walker, Dina Brooks, Roger Goldstein
| Articolo seguente Articolo seguente
  • Pectoralis muscle area and its association with indices of disease severity in interstitial lung disease
  • Yannick Molgat-Seon, Sabina A. Guler, Carli M. Peters, Dragoş M. Vasilescu, Joseph H. Puyat, Harvey O. Coxson, Christopher J. Ryerson, Jordan A. Guenette

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.