Abbonarsi

Significance of Tip Apex Distance in Intertrochanteric Fracture femur managed with Proximal femoral nailing - 06/10/21

Doi : 10.1016/j.otsr.2021.103009 
Vikram Khanna a, b, , Mukesh Tiwari b
a Department of Orthopaedics, Ranjana Hospital, Allahabad, India 
b Department of Orthopaedics, National Institute of Medical Sciences, Jaipur, India 

Corresponding author at: Department of orthopaedics, Ranjana Hospital, 13, D-Road, 211003 Allahabad, India.Department of orthopaedics, Ranjana Hospital13, D-RoadAllahabad211003India

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Tip Apex distance (TAD) is well established method of prediction of outcome in intertrochanteric fractures managed by Dynamic Hip Screw. This retrospective study was done to assess the significance of Tip Apex Distance in the management of the intertrochanteric fractures by Proximal femoral nail.

Material and methods

The study was done in a tertiary care centre where 174 follow-up patients operated for intertrochanteric fractures with proximal femoral nail were included in the study. The radiological outcome of patients was assessed using the neck shaft angle, neck length and the offset whereas the functional status was assessed using the Harris hip score and the Lower extremity functional scoring system. These functional and radiological outcomes were compared with the TAD for any significant findings.

Results

The tip apex distance on the postoperative X-ray was found to be 22.93+3.88mm. The Lower Extremity Functional Score was found to be 70.71+8.153. The Harris Hip Score was found to be 85.408+9.586. Change in the neck length as compared to the uninjured hip was found to be 1.46+1.705. Change in the offset and neck shaft angle was 1.38+1.567 and -2.61+1.27 respectively. There were 8 cases of screw cut out and 8 cases of superficial infection.

Discussion

The Harris hip score and the LEFS increased with decreasing values of the Tip Apex distance. The Neck shaft angle, Neck length and the offset all decreased with the increase in the Tip Apex Distance. The Harris hip score and the LEFS decreased with the decrease in the Neck shaft angle, Neck length and the offset. On examining the 2 groups one with TAD <25mm and the other with TAD >25mm it was seen that both functionally and radiologically, the outcome was better in the group having TAD<25mm.

Conclusion

This study indicates that the Tip Apex Distance can be used as a useful predictor of the outcome of the proximal femoral nail in intertrochanteric fractures.

Level of evidence

IV.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Proximal femur nailing, Intertrochanteric fracture, Tip apex distance, Harris hip score, Lower extremity functional scoring system, Neck shaft angle


Mappa


© 2021  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 6

Articolo 103009- ottobre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Trochanteric fractures treated by internal fixation using short intramedullary nails: Does the visual intraoperative estimation of the Tip-Apex Distance (TAD) concur with its digital postoperative measurement?
  • Adrien Drouinaud, Armand Alain, Sébastien Caudron, Thibaut Cunique, Emilie Auditeau, Pierre-Sylvain Marcheix
| Articolo seguente Articolo seguente
  • The influence of proximal femur canal size on reduction of intertrochanteric fracture with cephalomedullary nail
  • Hsuan-Hsiao Ma, Chao-Ching Chiang, Chun-Cheng Lin, Chien-Shun Wang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.