Abbonarsi

Parallel and non-parallel cannulated screw fixation complications in femoral neck fractures: A systematic review and meta-analysis - 06/10/21

Doi : 10.1016/j.otsr.2021.103005 
Eic Ju Lim a, Beom-Su Kim b, Chul-Ho Kim c,
a Department of Orthopaedic Surgery, Chungbuk National University Hospital, Chungbuk National University College of Medicine, Chungbuk National University, Cheongju, Republic of Korea 
b Department of Orthopaedic Surgery, Gachon University Gil Medical Center, Incheon, Republic of Korea 
c Department of Orthopaedic Surgery, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea 

Corresponding author at: Department of Orthopaedic Surgery, Chung-Ang University Hospital, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-ku, Seoul, 06973, Republic of Korea.Department of Orthopaedic Surgery, Chung-Ang University Hospital, Chung-Ang University College of Medicine102 Heukseok-ro, Dongjak-kuSeoul06973Republic of Korea

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Since its introduction in the early 1960s, the multiple cannulated screw fixation method has been developed for use in femoral neck fractures (FNFs); however, the parallelism of screws remains controversial.

Materials and methods

MEDLINE, Embase, and the Cochrane Library were systematically searched for studies published before June 2, 2020, that compared the use of parallel and non-parallel screw fixation for the treatment of FNF. The pooled analysis was designed to identify differences between the two groups and focused on postoperative complications, including fracture nonunion and osteonecrosis of the femoral head (ONFH).

Results

Over four studies, we enrolled 445 patients, including 195 patients with fixed FNF with parallel trajectory screws and 250 patients with fixed FNF with non-parallel screws. The pooled analysis showed no difference in the nonunion rates (odds ratio (OR)=0.91; 95% confidence interval (CI), 0.24–3.44; p=0.89) and no significant difference in the incidence of ONFH between parallel and non-parallel screw fixation (OR=0.74; 95% CI: 0.21–2.63; p=0.64).

Conclusions

The results of this meta-analysis reveal that screw parallelism in multiple cannulated screw fixation of FNF has no relationship with either the fracture nonunion rate or the incidence of postoperative ONFH.

Level of evidence

III; meta-analysis.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Multiple cannulated screw, Femoral neck fracture, Parallel, Non-parallel, Diverge, Cross, Meta-analysis


Mappa


© 2021  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 6

Articolo 103005- ottobre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
  • Marcin Ceynowa, Krzysztof Zerdzicki, Pawel Klosowski, Rafa? Pankowski, Marek Roc?awski, Tomasz Mazurek

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.