Quantitative and qualitative optimisation of dosimetry in computed tomography explorations of the temporal bone using two iterative reconstruction algorithms - 28/10/21

Doi : 10.1016/j.neuri.2021.100017 
Olivier Legeas a, David Bourhis b, Marc Garetier c, Adele Pennaneach d, Philippe Meriot a, Julien Ognard a, e, f, ⁎ , Douraied Ben Salem a, e, f
a Imaging Unit, University Hospital of Brest, Bd Tanguy Prigent, 29609 Brest Cedex, France 
b Radiation Physics and Protection Unit, University Hospital of Brest, Bd Tanguy Prigent, 29609 Brest Cedex, France 
c Imaging Unit, Military Teaching Hospital of Brest, Rue Colonel Fonferrier, 29240 Brest Cedex, France 
d Radiology Unit, Cornouaille Hospital of Quimper, 14Bis Avenue Yves Thépot, 29107 Quimper cedex, France 
e Laboratoire de traitement de l'information médicale—LaTIM (Inserm UMR 1101), 22, avenue Camille Desmoulins, CS 93837-29238 Brest Cedex 3, France 
f Clinical Forensic Medicine and Pathology, University Hospital of Brest, Bd Tanguy Prigent, 29609 Brest Cedex, France 

⁎Corresponding author at: Medical Imaging Service, University Hospital of Cavale Blanche, Bd Tanguy Prigent, 29609 Brest Cedex, France.Medical Imaging ServiceUniversity Hospital of Cavale BlancheBd Tanguy PrigentBrest Cedex29609France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Highlights

•
Analysis of Iterative Reconstruction algorithms on phantoms help to maximise dose reduction while maintaining a desired level of readability.
•
We measured in an image quality phantom the evolution of the Contrast-to-Noise Ratio for each IR algorithm depending on the CDTIvol.
•
Acquisition parameters were established involving the anthropomorphic phantom for an evaluation of the image quality at each iteration degree.
•
The optimal use were: Siemens: SAFIRE 3 with a CDTIvol with a dose reduction of 65%; GE: ASiR 20% with a dose reduction of 20%.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Purpose: Iterative reconstruction (IR) has recently demonstrated its ability to reduce the dose of X-rays used in the exploration of several anatomical regions. However, there is no study involving a qualitative and quantitative comparison of the various IRs available for exploring the temporal bone. The aim of this study is to analyse two IR algorithms (ASiR®, statistical iterative reconstruction and SAFIRE®, model based iterative reconstruction). Methods: Using a Catphan® phantom, we studied the quantitative relationship of the contrast on noise/CDTIvol/IR. We verified the absence of a reduction in spatial resolution during the use of IRs by measuring MTF50%. Based on these data we acquired a series of images on an anthropomorphic phantom with an authentic human temporal bone for each level of iteration; the purpose of this was to evaluate them qualitatively. The CDTIvol of temporal bone IRs was adjusted based on the measurements taken with the Catphan phantom in order to acquire images with a constant CNR. Results: The resulting measurements demonstrated a reduction in noise without a loss of spatial resolution in the two manufacturers' systems. The quantitative study by four radiologists allowed us to optimise CDTIvol and the level of iteration. This optimisation made it possible to reduce the dose in the two manufacturers' systems, and the most effective of these algorithms enabled a reduction in CDTIvol of 64.6% during explorations of the temporal bone. Conclusion: The two analysed iterative reconstruction algorithms responded well to the objectives of dose reduction in the exploration of the temporal bone.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Iterative reconstruction, Dosimetry, ASiR, SAFIRE, Temporal bone


Mappa


☆ This article has been handled by another Editor, Jean-Christophe Gentric during the whole editorial process.


© 2021  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 1 - N° 4

Articolo 100017- dicembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Contents
| Articolo seguente Articolo seguente
  • Quantitative evaluation of gray matter alterations in patients with mesial temporal lobe epilepsy (MTLE)
  • Zhensheng Li, Quwen Gao, Kairun Peng, Jian Lin, Wei Wang, Weimin Wang, Bingmei Deng

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.