Abbonarsi

Minimising radiation exposure to the surgeon in minimally invasive spine surgeries: A systematic review of 15 studies - 29/10/21

Doi : 10.1016/j.otsr.2020.102795 
Shahswar Arif a, Zarina Brady a, , Yavor Enchev a, b, Nikolay Peev c, Elitsa Encheva a
a Medical university of Varna, ul. “Professor Marin Drinov” 55, 9002 Center Varna, Bulgaria 
b Department of neurosurgery, medical university of Varna, university hospital “St. Marina”, Varna, Bulgaria 
c Department of neurosurgery, Royal Victoria hospital, Belfast health and social care trust, Belfast, Northern Ireland, United Kingdom 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Intraoperative imaging in minimally invasive spinal surgeries is associated with significant radiation exposure to surgeons, which overtime can lead to serious health hazards including malignancy. In this study, the authors conducted a systematic review to evaluate the efficacy of navigation assisted fluoroscopy methods on radiation exposure to the surgeon in minimally invasive spine surgeries, percutaneous endoscopic lumbar discectomy/percutaneous endoscopic transforaminal discectomy versus minimally invasive spine transforaminal lumbar interbody fusion (PELD/PETD versus MIS-TLIF).

Methods

A systematic literature search was conducted using PUBMED/MEDLINE on 20th July, 2020. Inclusion criteria were applied according to study design, surgical technique, spinal region, and language. Data extracted included lumbar segment, average operation time (min), fluoroscopic time (s), and radiation dose (μSV), efficacy of modified navigation versus conventional techniques; on reducing operation, fluoroscopy times and effective radiation dose.

Results

Fifteen studies (ten prospectives, and five retrospectives) were included for quantitative analysis. PELD recorded a shorter operation time (by 126.3min, p<0.001) and fluoroscopic time (by 22.9s, p=0.3) than MIS-TLIF. The highest radiation dose/case (μSV) for both techniques were recorded at the surgeon's: finger, chest, neck and eye. The effective dose for MIS-TLIF was 30μSV higher than PELD. Modified navigation techniques recorded a shorter operation time (by 15.9min, p=0.3); fluoroscopy time (by 289.8s, p=0.3); effective radiation dose (by 169.5μSV, p=0.3) than conventional fluoroscopy methods.

Discussion

This systematic literature review showed that although navigation assisted fluoroscopy techniques are superior to conventional methods in minimising radiation exposure, lack of statistical significance warrants future randomised controlled trials, to solidify their efficacy in reducing radiation related hazards.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Radiation exposure, Navigation assisted, Minimally invasive spine surgeries, PELD, MIS-TLIF


Mappa


© 2020  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 7

Articolo 102795- novembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Diagnosis of reoperated cervical non-union: Multicenter retrospective study about 45 patients
  • Maxime Huneidi, Yves Ntilikina, Ibrahim Obeid, Benjamin Bouyer, Fahed Zairi, Paulo Marinho, Yann-Philippe Charles, Jean-Marc Vital, Olivier Gille, Louis Boissière
| Articolo seguente Articolo seguente
  • Morbidity and clinicoradiological outcomes of anterior lumbar arthrodesis using tantalum intervertebral implants
  • Yann Breton, Jonathan Lebhar, Antoine Bourgoin, Pierre Kriegel, Patrick Chatellier, Mickaël Ropars

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.