The protective effect of tight-fitting powered air-purifying respirators during chest compressions - 29/10/21

Doi : 10.1016/j.ajem.2021.06.012 
Yukari Goto, MD a, , Naruhiro Jingushi, MD a , Hiroaki Hiraiwa, PhD a, b , Hiroaki Ogawa, MD a , Yoshinori Sakai, MD a , Daisuke Kasugai, MD a , Taku Tanaka, PhD a , Michiko Higashi, MD a , Takanori Yamamoto, MD a , Atsushi Numaguchi, MD a
a Department of Emergency and Critical Care, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi 466-8560, Japan 
b Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai, Showa, Nagoya, Aichi 466-8560, Japan 

Corresponding author.

Abstract

Background

Airborne personal protective equipment is required for healthcare workers when performing aerosol-generating procedures on patients with infectious diseases. Chest compressions, one of the main components of cardiopulmonary resuscitation, require intense and dynamic movements of the upper body. We aimed to investigate the protective effect of tight-fitting powered air-purifying respirators (PAPRs) during chest compressions.

Methods

This single-center simulation study was performed from February 2021 to March 2021. The simulated workplace protection factor (SWPF) is the concentration ratio of ambient particles and particles inside the PAPR mask; this value indicates the level of protection provided by a respirator when subjected to a simulated work environment. Participants performed continuous chest compressions three times for 2 min each time, with a 4-min break between each session. We measured the SWPF of the tight-fitting PAPR during chest compression in real-time mode. The primary outcome was the ratio of any failure of protection (SWPF <500) during the chest compression sessions.

Results

Fifty-four participants completed the simulation. Overall, 78% (n = 42) of the participants failed (the measured SWPF value was less than 500) at least one of the three sessions of chest compressions. The median value and interquartile range of the SWPF was 4304 (685–16,191). There were no reports of slipping down of the respirator or mechanical failure during chest compressions.

Conclusions

Although the median SWPF value was high during chest compressions, the tight-fitting PAPR did not provide adequate protection.

Il testo completo di questo articolo è disponibile in PDF.

Highlights

Powered air-purifying respirators (PAPRs) is a type of personal protective equipment.
We measured the protective effect of tight-fitting PAPRs during chest compressions.
Tight-fitting PAPR did not provide adequate protection during chest compression.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Powered air-purifying respirators, Aerosol-generating procedures, Chest compression

Abbreviations : Coronavirus disease 2019, SARS-CoV-2, AGP, PPE, CPR, NIOSH, PAPR, HCW, APF, FF, SWPF, IQR


Mappa


© 2021  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 49

P. 172-177 - novembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Rates and clinical impact of discordant X-ray and CT imaging in transfers to a pediatric emergency department
  • Jason P. Miller, Ciara Ivanics, Kristina Zalewski, Swati S. Mody, Nirupama Kannikeswaran
| Articolo seguente Articolo seguente
  • Association between patients' body mass index and emergency department wait times: A multicenter observational cohort investigation by the reducing disparities increasing equity in emergency medicine (REDEEM) study group
  • Isabella M. Lichen, Venkatesh R. Bellamkonda, Ronna L. Campbell, Sean M. Phelan, Joel R. Anderson, Aidan F. Mullan, Kit Knier, Annie T. Sadosty

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.