Highlights

Deep learning algorithms lack real-world external validation prior to clinical use.
The tested deep learning algorithm shows strong diagnostic performance in children.
Sensitivity of the tested algorithm is lower in children under 4 years.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Purpose

The purpose of this study was to conduct an external validation of a fracture assessment deep learning algorithm (Rayvolve®) using digital radiographs from a real-life cohort of children presenting routinely to the emergency room.

Materials and methods

This retrospective study was conducted on 2634 radiography sets (5865 images) from 2549 children (1459 boys, 1090 girls; mean age, 8.5 ± 4.5 [SD] years; age range: 0–17 years) referred by the pediatric emergency room for trauma. For each set was recorded whether one or more fractures were found, the number of fractures, and their location found by the senior radiologists and the algorithm. Using the senior radiologist diagnosis as the standard of reference, the diagnostic performance of deep learning algorithm (Rayvolve®) was calculated via three different approaches: a detection approach (presence/absence of a fracture as a binary variable), an enumeration approach (exact number of fractures detected) and a localization approach (focusing on whether the detected fractures were correctly localized). Subgroup analyses were performed according to the presence of a cast or not, age category (0–4 vs. 5–18 years) and anatomical region.

Results

Regarding detection approach, the deep learning algorithm yielded 95.7% sensitivity (95% CI: 94.0–96.9), 91.2% specificity (95% CI: 89.8–92.5) and 92.6% accuracy (95% CI: 91.5–93.6). Regarding enumeration and localization approaches, the deep learning algorithm yielded 94.1% sensitivity (95% CI: 92.1–95.6), 88.8% specificity (95% CI: 87.3–90.2) and 90.4% accuracy (95% CI: 89.2–91.5) for both approaches. Regarding age-related subgroup analyses, the deep learning algorithm yielded greater sensitivity and negative predictive value in the 5–18-years age group than in the 0–4-years age group for the detection approach (P < 0.001 and P = 0.002) and for the enumeration and localization approaches (P = 0.012 and P = 0.028). The high negative predictive value was robust, persisting in all of the subgroup analyses, except for patients with casts (P = 0.001 for the detection approach and P < 0.001 for the enumeration and localization approaches).

Conclusion

The Rayvolve® deep learning algorithm is very reliable for detecting fractures in children, especially in those older than 4 years and without cast.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Radiographs, Deep learning algorithm, Artificial intelligence, Fractures, Pediatric

Abbreviations : CI, DICOM, FN, FP, LR-, LR+, NPV, PACS, PPV, ROI, TN, TP


Mappa


© 2021  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 3

P. 151-159 - marzo 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Local recurrence following complete radiologic response in patients treated with transarterial chemoembolization for hepatocellular carcinoma
  • Shamar Young, Tina Sanghvi, Sandeep Sharma, Cameron Richardson, Nathan Rubin, Masters Richards, Donna D'Souza, Siobhan Flanagan, Jafar Golzarian
| Articolo seguente Articolo seguente
  • Computed tomography angiography for quantification of cerebral vasospasm following aneurysmal subarachnoid hemorrhage
  • Mariam Soumah, Jonathan Brami, Davide Simonato, Benjamin Chousterman, Antoine Guillonnet, Anne-Laure Bernat, Emmanuel Houdart, Marc-Antoine Labeyrie

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.