Abbonarsi

Relationship Between Macular Microvasculature and Visual Acuity in Advanced and Severe Glaucoma - 23/03/22

Doi : 10.1016/j.ajo.2021.10.005 
YUN HSIA a, b, c, TSING-HONG WANG b, c, JEHN-YU HUANG b, c, CHIEN-CHIA SU b, c,
a National Taiwan University Hospital, Jin-Shan Branch, New Taipei City, Taiwan 
b Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan (Y.H., T.-H.W., J.-Y.H., C.-C.S.); 
c College of Medicine, National Taiwan University, Taipei, Taiwan (T.-H.W., J.-Y.H., C.-C.S.) 

Inquiries to Chien-Chia Su, Department of Ophthalmology, National Taiwan University Hospital, No. 7, Chung-Shan S Rd, Taipei, Taiwan.Department of Ophthalmology

Riassunto

Purpose

To evaluate the correlation between structural parameters and visual acuity (VA) in advanced glaucoma.

Design

Prospective, cross-sectional study.

Methods

A total of 238 eyes from 238 patients (82 were men and mean ± SD age was 59.9 ± 13.8 years) from a tertiary center were divided into an advanced (mean deviation of 24-2 visual field tests from –12.01 to –20.0 dB) and severe (< –20 dB) glaucoma group. Structural parameters were obtained by RTVue (Optovue Inc) optical coherence tomography and angiography. Pearson correlation, partial correlation adjusted for age and axial length, and receiver operating characteristic curves to detect decreased VA (<20/25) were performed.

Results

In the advanced glaucoma group (133 eyes), superficial (Pearson correlation coefficient, r = –0.46, P < .001; partial correlation coefficient, r' = –0.30, P < .001) and deep macular vessel densities (VDs) (r = –0.47, P < .001; r' = –0.30, P < .001) showed highest correlation with VA. The area under the receiver operating characteristic curves of the superficial parafoveal/macular VDs were 0.816 (95% CI, 0.735–0.897) and 0.808 (95% CI, 0.725–0.891), respectively. In the severe glaucoma group (105 eyes), deep nasal grid VD (r = –0.31, P = 0.002; r' = –0.35, P < .001) showed highest correlation with VA. Deep macular VD showed better correlation with VA than other structural parameters. The area under the receiver operating characteristic curves of deep macular VD and deep nasal grid VD were 0.740 (95% CI, 0.632–0.849) and 0.748 (95% CI, 0.640–0.857), respectively.

Conclusions

Macular VD showed better correlation with VA in advanced glaucoma. Deep macular VD, especially nasal grid, may be a promising structural parameter in severe glaucoma.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Supplemental Material available at AJO.com. Accepted for publication Oct 5, 2021.


© 2021  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 236

P. 154-163 - aprile 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Strabismus Surgery Decreases the Risk of Injuries in Pediatric Patients in the OptumLabs Data Warehouse
  • Stacy L. Pineles, Michael X. Repka, Fei Yu, Federico G. Velez, Claudia Perez, Danielle Sim, Anne L. Coleman
| Articolo seguente Articolo seguente
  • Healthcare Resource Utilization and Cost of Care in Patients With Periocular Basal Cell Carcinoma: A Real-World Study
  • Alon Kahana, Karen Bartley, Craig S. Meyer, Arpamas Seetasith, Janet Lee, Edward McKenna

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.