Abbonarsi

The Weiss Ring, a Major Confounding Factor For Measurements of Peripapillary Retinal Nerve Fiber Layer Thickness : Short title: The Impact of the Weiss Ring On RNFL Thickness Measurements - 23/05/22

Doi : 10.1016/j.ajo.2022.01.001 
Min-Woo Lee 1, Min-Su Kim 2, Hwa-Young Yu 1, Kee-Sup Park 1, Young-Hoon Lee 1, Jung-Yeul Kim 2, ⁎
1 From Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Republic of Korea (M.W.L., H.Y.Y., K.S.P., Y.H.L.) 
2 Department of Ophthalmology, Chungnam National University College of Medicine,Daejeon, Republic of Korea (M.S.K., J.Y.K.) 

⁎Inquiries to Jung-Yeul Kim, Department of Ophthalmology, Chungnam National University Hospital, #640 Daesa-dong, Jung-gu, Daejeon, 301-721, KoreaDepartment of OphthalmologyChungnam National University Hospital#640 Daesa-dong, Jung-guDaejeon301-721Korea

Highlights

•
Eyes with a Weiss ring showed thinner mean and inferior peripapillary retinal nerve fiber layer (pRNFL) thicknesses than normal controls, which could be a major confounding factor for analyses of pRNFL changes, especially in glaucoma patients.

Il testo completo di questo articolo è disponibile in PDF.

Riassunto

Purpose

To identify how the Weiss ring affects the measurement of mean and sectoral peripapillary retinal nerve fiber layer (pRNFL) thicknesses.

Design

Retrospective, cross-sectional study.

Methods

Subjects were divided into two groups: controls (control group) and subjects in which a Weiss ring was visible on optical coherence tomography fundus images (WR group). Mean and sectoral pRNFL thicknesses were compared between the two groups.

Results

A total of 205 eyes were enrolled: 131 eyes in the control group and 74 eyes in the WR group. The mean pRNFL thicknesses of the control group and WR group were 97.2 ± 6.7 µm and 94.6 ± 10.8 µm, respectively (P = .042). In sectoral thickness, the inferior sector of the WR group was 112.1 ± 23.2 µm, which was significantly thinner than that of the control group (125.5 ± 13.3 µm; P < .001). The Weiss ring was located in 10 eyes (13.5%) in the superior sector, 7 eyes (9.5%) in the temporal sector, 40 eyes (54.1%) in the inferior sector, and 17 eyes (23.0%) in the nasal sector. In analyses of reproducibility, the coefficient of variation and intraclass coefficient of the inferior sector measurement were 10.90% and 0.409, respectively, indicating low reliability of the measurement.

Conclusions

Eyes with a Weiss ring showed thinner mean and inferior pRNFL thicknesses than normal controls, which would be a measurement error caused by the Weiss ring. This could be a major confounding factor for analyses of pRNFL changes, especially in glaucoma patients.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2022  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 238

P. 134-140 - giugno 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Impact of Taping The Upper Mask Edge On Ocular Surface Stability and Dry Eye Symptoms
  • Sridevi Nair, Manpreet Kaur, Ramkishor Sah, Jeewan S. Titiyal
| Articolo seguente Articolo seguente
  • Micronutrients and Diabetic Retinopathy: Evidence From The National Health and Nutrition Examination Survey and a Meta-analysis
  • Ruilin Xiong, Yixiong Yuan, Zhuoting Zhu, Yi Wu, Jason Ha, Xiaotong Han, Wei Wang, Mingguang He

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.