Abbonarsi

Predicting Visual Fields From Optical Coherence Tomography via an Ensemble of Deep Representation Learners - 23/05/22

Doi : 10.1016/j.ajo.2021.12.020 
Georgios Lazaridis a, b, , Giovanni Montesano a, c, Saman Sadeghi Afgeh d, Jibran Mohamed-Noriega a, e, Sebastien Ourselin f, Marco Lorenzi g, David F. Garway-Heath a
a From the NIHR Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology (G.L., G.M., J.M.-N., D.F.G.-H.), London, United Kingdom 
b Centre for Medical Image Computing, University College London (G.L.), London, United Kingdom 
c Optometry and Visual Sciences, City, University of London, London, United Kingdom 
d Data Science Institute, City University (S.S.A.), London, United Kingdom 
e Departamento de Oftalmología, Hospital Universitario (J.M.-N.), UANL, México 
f School of Biomedical Engineering and Imaging Sciences, King's College London (S.O.), London, United Kingdom and 
g Université Côte d'Azur, Inria Sophia Antipolis, Epione Research Project (M.L.), Valbonne, France 

Inquiries to Georgios Lazaridis, Centre for Medical Image Computing (CMIC), University College London, 90 High Holborn, Floor 1, London, WC1V 6LJ.Centre for Medical Image Computing (CMIC)University College London90 High Holborn, Floor 1LondonWC1V 6LJ

Riassunto

PURPOSE

To develop and validate a deep learning method of predicting visual function from spectral domain optical coherence tomography (SD-OCT)–derived retinal nerve fiber layer thickness (RNFLT) measurements and corresponding SD-OCT images.

DESIGN

Development and evaluation of diagnostic technology.

METHODS

Two deep learning ensemble models to predict pointwise VF sensitivity from SD-OCT images (model 1: RNFLT profile only; model 2: RNFLT profile plus SD-OCT image) and 2 reference models were developed. All models were tested in an independent test-retest data set comprising 2181 SD-OCT/VF pairs; the median of ∼10 VFs per eye was taken as the best available estimate (BAE) of the true VF. The performance of single VFs predicting the BAE VF was also evaluated. The training data set comprised 954 eyes of 220 healthy and 332 glaucomatous participants, and the test data set, 144 eyes of 72 glaucomatous participants. The main outcome measures included the pointwise prediction mean error (ME), mean absolute error (MAE), and correlation of predictions with the BAE VF sensitivity.

RESULTS

The median mean deviation was –4.17 dB (–14.22 to 0.88). Model 2 had excellent accuracy (ME 0.5 dB, SD 0.8) and overall performance (MAE 2.3 dB, SD 3.1), and significantly (paired t test) outperformed the other methods. For single VFs predicting the BAE VF, the pointwise MAE was 1.5 dB (SD 0.7). The association between SD-OCT and single VF predictions of the BAE pointwise VF sensitivities was R2 = 0.78 and R2 = 0.88, respectively.

CONCLUSIONS

Our method outperformed standard statistical and deep learning approaches. Predictions of BAEs from OCT images approached the accuracy of single real VF estimates of the BAE.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 238

P. 52-65 - giugno 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Corneal Biometric Features and Their Association With Axial Length in High Myopia
  • Guangming Jin, Zhenzhen Liu, Lanhua Wang, Yi Zhu, Lixia Luo, Yizhi Liu
| Articolo seguente Articolo seguente
  • Intraocular Inflammation in Eyes Operated for Late In-the-bag intraOcular lens dislocatioN (LION): A Randomized Clinical Trial
  • HELLE MEDIN, MARIUS DALBY, INGEBORG SLØRDAHL HJORT KURE, MIA KARABEG, LIV DROLSUM, OLAV KRISTIANSLUND

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.