A Fully Automated Segmentation and Morphometric Parameter Estimation System for Assessing Corneal Endothelial Cell Images - 13/06/22

Doi : 10.1016/j.ajo.2022.02.026 
Jing-Hao Qu a, b, 1, Xiao-Ran Qin c, 1, Rong-Mei Peng a, b, Ge-Ge Xiao a, b, Jian Cheng c, Shao-Feng Gu a, b, Hai-Kun Wang a, b, Jing Hong a, b,
a Department of Ophthalmology, Peking University Third Hospital, Beijing, China (J-H.Q, R-M.P, G-G.X, S-F.G, H-K.W, J.H) 
b Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China (J-H.Q, R-M.P, G-G.X, S-F.G, H-K.W, J.H) 
c Research Center for Brain-inspired Intelligence, Institute of Automation, Chinese Academy of Sciences, Beijing, China (X-R.Q, J.C) 

Inquiries to Dr Jing Hong, No. 49 Garden North Road, Haidian, Beijing, 100191, China.No. 49 Garden North RoadHaidianBeijing100191China

Riassunto

Purpose

To develop a fully automated segmentation and morphometric parameter estimation system for assessing corneal endothelial cells from in vivo confocal microscopy images.

Design

Artificial intelligence (neural network) study.

Methods

First, a fully automated deep learning system for assessing corneal endothelial cells was developed using the development set (from 99 subjects). Second, 184 images (from 97 subjects) were used to construct the testing set to evaluate the clinical validity and usefulness of the automated segmentation and morphometric system. Third, the automatically calculated endothelial cell density (ECD) values, Topcon's cell density, and manually calculated ECD were compared.

Results

After slit lamp examination, 88 healthy subjects, 2 Fuchs endothelial dystrophy patients, and 7 corneal endotheliitis patients were identified among the 97 subjects in the testing set. The automatedly estimated morphometric parameters for the testing set were an average number of 234 cells, an ECD of 2592 cells/mm2, a coefficient of variation in the cell area of 32.14%, and a percentage of hexagonal cells of 54.16%. Pearson's correlation coefficient between the automated ECD and Topcon's cell density and between the manually calculated ECD and Topcon's cell density was 0.932 (P < .01) and 0.818 (P < .01), respectively. The Bland-Altman plot of Topcon's cell density and the automated ECD yielded 95% limits of agreement between 271.94 and –572.46 (concordance correlation coefficient = 0.9).

Conclusions

A fully automated method for segmenting corneal endothelial cells and estimating morphometric parameters using in vivo confocal microscopy images is more efficient and accurate for assessing the normal corneal endothelium.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : corneal endothelial cells, in vivo confocal microscopy, deep learning


Mappa


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 239

P. 142-153 - luglio 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Pediatric Cataract Surgery Following Treatment for Retinoblastoma: A Case Series and Systematic Review
  • Stephanie N. Kletke, Ashwin Mallipatna, Kamiar Mireskandari, Brenda L. Gallie, Asim Ali
| Articolo seguente Articolo seguente
  • Gender Diversity on Corporate Boards Associated with Ophthalmology
  • Dominique Alexis, Corrinne Fahl, Eve Higginbotham, J. Bronwyn Bateman

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.