Abbonarsi

Fatigue Loading Effect in Custom-Made All-on-4 Implants System: A 3D Finite Elements Analysis - 20/09/22

Doi : 10.1016/j.irbm.2021.06.008 
A. Darwich a, b, A. Alammar c, O. Heshmeh c, S. Szabolcs d, H. Nazha d,
a Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria 
b Faculty of Technical Engineering, University of Tartous, Syria 
c Faculty of Dentistry, Damascus University, Damascus, Syria 
d Faculty of Mechanical Engineering and Informatics, University of Miskolc, Miskolc, Hungary 

Corresponding author.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

The biomedical response of dental implants during static and fatigue loading were assessed.
Fatigue loading caused greater stresses in comparison with static loading.
Cortical bone showed higher stress values than trabecular bone under either static or fatigue loading.
Vertical implants showed more homogenous behavior in the system.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Objectives

This study aims to evaluate the fatigue stress around custom-made all-on-4 implants system to find out which type of implants have a better performance under different graded multidirectional occlusal forces.

Material and methods

3D normal and implanted models simulating the “All-on-4” concept were created and analyzed under three different conditions of occlusal loadings. Two types of static and fatigue were applied. Stress distribution was analyzed based on von Mises and Goodman theories in ANSYS environment in addition to the safety factor. Statistical tests were performed to assess the significance of the results as well as the reproducibility of the results.

Results

The results showed stress increasing reaching a value of 48%, 29% in tilted implants compared to vertical implants and normal cases respectively. In contrast, tilted implants appeared to be less stable (safety factor may reach 0.7) and they may fail during the application of occlusal forces. The safety factor of cortical bone decreased by about 91% in the implanted model compared to the normal model, indicating a higher possibility of bone remodeling around the bone.

Conclusion

The orientation and position of occlusal forces had an important influence on stress distribution between the implant and the surrounding bone, and fatigue loading caused greater stresses in comparison with static loading. Lower amounts of stress were found in the vertical implants, ensuring a higher safety factor and a longer clinical service. In contrast, the critical safety factor values are observed in tilted implants, which may fail under the influence of applied occlusal forces.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : All-on-four concept, Fatigue loading, Dental implant, Finite element analysis


Mappa


© 2021  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 43 - N° 5

P. 372-379 - ottobre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Fast Evaluation of Unhealthy and Healthy Neonates Using Hyperspectral Features on 700-850 Nm Wavelengths, ROI Extraction, and 3D-CNN
  • M. Cihan, M. Ceylan, H. Soylu, M. Konak
| Articolo seguente Articolo seguente
  • Time Domain Analysis of Heart Rate Variability Signals in Valence Recognition for Children with Autism Spectrum Disorder (ASD)
  • B. Anandhi, S. Jerritta, I.G. Anusuya, H. Das

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.