Waveforms-guided cycling-off during pressure support ventilation improves both inspiratory and expiratory patient-ventilator synchronisation - 24/11/22

Doi : 10.1016/j.accpm.2022.101153 
Francesco Mojoli a, b, , Anita Orlando a, Isabella Maria Bianchi b, Roberta Puce a, Eric Arisi a, Giulia Salve b, Giuseppe Maggio a, Silvia Mongodi a, Marco Pozzi a
a Anaesthesia and Intensive Care, Emergency Department, Fondazione IRCCS Policlinico S. Matteo, Viale Golgi 19, 27100, Pavia, Italy 
b Anaesthesia, Intensive Care and Pain Therapy, Department of Clinical - Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Pavia, Italy 

Corresponding author.

Highlights

Synchronisation requires time at the patient’s bedside.
Default settings are often inadequate.
Patients often require ventilator settings re-adjustments.
It is important to optimise cycling-off phase to improve synchronisation.
By acting on cycling one can facilitate the triggering phase as well.
Automated software can manage synchronisation during pressure support ventilation.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Objective

To test the performance of a software able to control mechanical ventilator cycling-off by means of automatic, real-time analysis of ventilator waveforms during pressure support ventilation.

Design

Prospective randomised crossover study.

Setting

University Intensive Care Unit.

Patients

Fifteen difficult-to-wean patients under pressure support ventilation.

Interventions

Patients were ventilated using a G5 ventilator (Hamilton Medical, Bonaduz, Switzerland) with three different cycling-off settings: standard (expiratory trigger sensitivity set at 25% of peak inspiratory flow), optimised by an expert clinician and automated; the last two settings were tested at baseline pressure support and after a 50% increase in pressure support.

Measurements and main results

Ventilator waveforms were recorded and analysed by four physicians experts in waveforms analysis. Major and minor asynchronies were detected and total asynchrony time computed.

Automation compared to standard setting reduced cycling delay from 407 ms [257-567] to 59 ms [22-111] and ineffective efforts from 12.5% [3.4-46.4] to 2.8% [1.9-4.6]) at baseline support (p < 0.001); expert optimisation performed similarly. At high support both cycling delay and ineffective efforts increased, mainly in the case of expert setting, with the need of reoptimisation of expiratory trigger sensitivity. At baseline support, asynchrony time decreased from 39.9% [27.4-58.7] with standard setting to 32% [22.3-39.4] with expert optimisation (p < 0.01) and to 24.4% [19.6-32.5] with automation (p < 0.001). Both at baseline and at high support, asynchrony time was lower with automation than with expert setting.

Conclusions

Cycling-off guided by automated real-time waveforms analysis seems a reliable solution to improve synchronisation in difficult-to-wean patients under pressure support ventilation.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : ICU, Auto, ETS, Std, Opti, PSV, CD, TD, IE, AT, RR, TV

Keywords : Asynchronies, Cycling, Pressure support ventilation, Mechanical ventilation, Patient-ventilator interaction, Hyperinflation


Mappa


© 2022  Société française d'anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 41 - N° 6

Articolo 101153- dicembre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Sample size considerations for studies comparing intubating conditions using quantitative monitoring versus a fixed interval during onset of neuromuscular blockade
  • Christophe Baillard, Catherine Tamrabet, Samia Ben Abdallah, Sophie Toussaint, Chérifa Cheurfa
| Articolo seguente Articolo seguente
  • A different approach to radial artery cannulation
  • Raghuraman M. Sethuraman, Purushotham Ramamurthy, Gayathri Ramesh, Shanmuga Priya Arulmozhi

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.